Renal Function in Patients with High Serum Fluoride Concentrations after Prolonged Sevoflurane Anesthesia

Author:

Higuchi Hideyuki,Sumikura Hiroyuki,Sumita Shinji,Arimura Shinya,Takamatsu Futoshi,Kanno Masuyuki,Satoh Tetsuo

Abstract

Background In studies of methoxyflurane-induced nephrotoxicity, renal-concentrating impairment has been observed only when serum inorganic fluoride concentrations exceed 50 microM. Prolonged sevoflurane anesthesia can result in serum inorganic fluoride concentrations in excess of 50 microM. The authors compared renal function after prolonged sevoflurane anesthesia with that after isoflurane anesthesia. In addition, they measured urinary excretion of N-acetyl-beta-glucosaminidase (NAG), a sensitive index of renal tubular damage, during the 3-day period after anesthesia. Methods Thirty-four healthy patients who underwent either sevoflurane (23 patients) or isoflurane (11 patients) anesthesia at a total gas flow of 61/min for orthopedic surgery scheduled to last at least 5 h were studied. At 16.5 h after cessation of anesthesia, patients were administered 10 units of vasopressin and urine was collected frequently thereafter for evaluation of urinary osmolality. In addition, urinary excretion of NAG was measured before and on days 1-3 after anesthesia. Based on whether peak fluoride concentrations exceeded 50 microM, 23 patients anesthetized with sevoflurane were assigned to a sevofluranehigh group (> 50 microM) or a sevofluranelow (< 50 microM) group. Results The eight patients in the sevofluranehigh group had a mean peak fluoride concentration of 57.5 +/- 4.3 microM. A significant, albeit weak, inverse correlation was found between peak fluoride concentration and maximal urinary osmolality after the injection of vasopressin (r = -0.42, P < 0.05). Mean maximum urinary osmolality tended to be lower in the sevofluranehigh group (681 +/- 60 mOsm/kg) than in the other two groups after administration of vasopressin, although the difference among the three groups did not quite reach a statistical significance (P = 0.068). One patient had a transient concentrating defect (maximum urinary osmolality = 390 mOsm/kg) on day 1 after anesthesia. Urinary excretion of NAG in both the sevofluranehigh and sevofluranelow groups was greater on days 2 and 3 after anesthesia than before anesthesia. The increase in urinary NAG excretion was dose related with sevoflurane, but there was no difference in results of routine laboratory renal tests on days 2 and 3 after anesthesia among the three groups. Conclusions The authors concluded that sevoflurane anesthesia results in increased serum fluoride concentration, a tendency toward decreased maximal ability to concentrate urine, and increased excretion of NAG. However, the increase in urinary NAG excretion was not indicative of clinically significant renal damage in these patients with no preexisting renal disease.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference31 articles.

Cited by 103 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3