Study of the “Sniffing Position” by Magnetic Resonance Imaging

Author:

Adnet Frédéric1,Borron Stephen W.2,Dumas Jean Luc3,Lapostolle Frédéric1,Cupa Michel4,Lapandry Claude1

Affiliation:

1. Assistant Professor.

2. Associate Professor, Department of Emergency Medicine, George Washington University.

3. Professor of Anatomy, Department of Radiology, Hôpital Avicenne, University Paris 13.

4. Professor of Anesthesiology and Chairman, Service d’Aide Mèdicale d’Urgence 93 and the Department of Anesthesiology.

Abstract

Background The "sniffing position" is widely considered essential to the performance of orotracheal intubation and has become the cornerstone of training in anesthesiology. However, the anatomic superiority of this patient head position has not been established. Methods Eight healthy young adult volunteers underwent magnetic resonance imaging scanning in three anatomic positions: head in neutral position, in simple extension, and in the "sniffing position" (neck flexed and head extended by means of a pillow). The following measurements were made on each scan: (1) the axis of the mouth (MA); (2) the pharyngeal axis (PA); (3) the laryngeal axis (LA); and (4) the line of vision. The various angles between these axes were defined: alpha angle between the MA and PA, beta angle between PA and LA, and delta angle between line of vision and LA. Results Both simple extension and sniffing positions significantly improved (P < 0.05) the delta angle associated with best laryngoscopic view. Our results show that the beta value increases significantly (P < 0.05) when the head position is shifted from the neutral position (beta = 7 +/- 6 degrees ) to the sniffing position (beta = 13 +/- 6 degrees ), and the alpha value slightly (but significantly) decreases (from 87 +/- 10 degrees to 63 +/- 11 degrees; P < 0.05). Anatomic alignment of the LA, PA, and MA axes is impossible to achieve in any of the three positions tested. There were no significant differences between angles observed in simple extension and sniffing positions. Conclusions The sniffing position does not achieve alignment of the three important axes (MA, PA, and LA) in awake patients with normal airway anatomy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference17 articles.

Cited by 134 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3