Optoacoustic, Noninvasive, Real-Time, Continuous Monitoring of Cerebral Blood Oxygenation: An In Vivo  Study in Sheep

Author:

Petrov Yuriy Y.1,Prough Donald S.2,Deyo Donald J.3,Klasing Manfred1,Motamedi Massoud4,Esenaliev Rinat O.5

Affiliation:

1. Senior Research Associate.

2. Professor and Chair of Anesthesiology.

3. Associate Professor, Department of Anesthesiology, University of Texas Medical Branch, Galveston, Texas.

4. Professor, Center for Biomedical Engineering.

5. Associate Professor, Director of Laboratory for Optical Sensing and Monitoring, Center for Biomedical Engineering, Department of Physiology and Biophysics and Department of Anesthesiology.

Abstract

Background Current, invasive cerebral oxygenation monitors require either retrograde jugular venous bulb cannulation or intraparenchymal probe insertion. There is no accurate, noninvasive, continuous monitor of cerebral blood oxygenation. Methods The authors designed, built, and tested novel optoacoustic instrumentation that continuously measures blood oxygenation in the superior sagittal sinus (SSS) in vivo in 12 anesthetized sheep. In this technique, laser pulses generate acoustic signals, the amplitudes and slopes of which are proportional to oxyhemoglobin saturation in the SSS. Optoacoustic signals from the SSS measured through the scalp and cranium were compared with directly measured oxyhemoglobin saturation in blood withdrawn from the cannulated SSS. Results In the first experiments (feasibility), FIO2 changes produced rapid corresponding changes in optoacoustic signals and arterial oxygen saturation. In the second experiments (validation), the authors correlated oxyhemoglobin saturation in the SSS with optoacoustic signals and developed quantifying algorithms. In eight of nine validation experiments, the authors quantified optoacoustic signals by subtracting the temporal profile at low FIO2 (0.08-0.1) from profiles at higher FIO2 and integrating those signals in the range from 3 to 5 micros. In each validation experiment, optoacoustic signals showed tight temporal association and good linear correlation with measured oxyhemoglobin saturation (r2 0.75 to 0.99 for eight individual experiments). Conclusions The optoacoustic system detects signals induced in the SSS and optoacoustic signals from the SSS linearly correlate with oxyhemoglobin saturation. The data suggest that the optoacoustic technique merits clinical evaluation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference21 articles.