High Carboxyhemoglobin Concentrations Occur in Swine during Desflurane Anesthesia in the Presence of Partially Dried Carbon Dioxide Absorbents

Author:

Frink Edward J.,Nogami Wallace M.,Morgan Scott E.,Salmon Roger C.

Abstract

Background Increased carboxyhemoglobin concentrations in patients receiving inhalation anesthetics (desflurane, enflurane, and isoflurane) have been reported. Recent in vitro studies suggest that dry carbon dioxide absorbents may allow the production of carbon monoxide. Methods The authors used high fresh oxygen flow (5 or 10 l/min) through a conventional circle breathing system of an anesthesia machine for 24 or 48 h to produce absorbent drying. Initial studies used 10 l/min oxygen flow with the reservoir bag removed or with the reservoir bag left in place during absorbent drying (this increases resistance to gas flow through the canister). A third investigation evaluated a lower flow rate (5 l/min) for absorbent drying. Water content of the absorbent and temperature were measured. Pigs received a 1.0 (human) minimum alveolar concentration desflurane anesthetic (7.5%) for 240 min using a 1 l/min oxygen flow rate with dried absorbent. Carbon monoxide concentrations in the circuit and carboxyhemoglobin concentrations in the pigs were measured. Results Pigs anesthetized with desflurane using Baralyme exposed to 48 h of 10 l/min oxygen flow (reservoir bag removed) had extremely high carboxyhemoglobin concentrations (more than 80%). Circuit carbon monoxide concentrations during desflurane anesthesia using absorbents exposed to 10 l/min oxygen flow (reservoir bag removed, 24 h) reached peak values of 8,800 to 13,600 ppm, depending on the absorbent used. Carboxyhemoglobin concentrations reached peak values of 73% (Baralyme) and 53% (soda lime). The water content of Baralyme decreased from 12.1 +/- 0.3% (mean +/- SEM) to as low as 1.9 +/- 0.4% at the bottom of the lower canister (oxygen flow direction during drying was from bottom to top). Absorbent temperatures in the bottom canister increased to temperatures as high as 50 degrees C. With the reservoir bag in place during drying (10 l/min oxygen flow), water removal from Baralyme was insufficient to produce carbon monoxide (lowest water content = 5.5%). Use of 5 l/min oxygen flow (reservoir bag removed) for 24 h did not reduce water content sufficiently to produce carbon dioxide with desflurane. Conclusions An oxygen flow rate of 10 l/min for 24 h in a conventional anesthesia circuit can dry carbon dioxide absorbents sufficiently to produce extremely high levels of carbon monoxide with high carboxyhemoglobin concentrations in desflurane-anesthetized pigs. When the reservoir bag is in place on the anesthesia machine or when a lower oxygen flow rate (5 l/min) is used, carbon dioxide absorbent drying still occurs, but 24-48-h exposure time is insufficient to allow for carbon monoxide production with desflurane.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference5 articles.

Cited by 62 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3