The Influence of Cuff Volume and Anatomic Location on Pharyngeal, Esophageal, and Tracheal Mucosal Pressures with the Esophageal Tracheal Combitube

Author:

Keller Christian1,Brimacombe Joseph2,Boehler Micheal3,Loeckinger Alexander4,Puehringer Friedrich1

Affiliation:

1. Associate Professor.

2. Professor, Department of Anaesthesia and Intensive Care, University of Queensland and James Cook University, Cairns Base Hospital.

3. Resident.

4. Consultant, Department of Anaesthesia and Intensive Care Medicine, Leopold-Franzens University.

Abstract

Background The authors determined the influence of cuff volume and anatomic location on pharyngeal, esophageal, and tracheal mucosal pressures for the esophageal tracheal combitube. Methods Twenty fresh cadavers were studied. Microchip sensors were attached to the anterior, lateral, and posterior surfaces of the distal and proximal cuffs of the small adult esophageal tracheal combitube. Mucosal pressure for the proximal cuff in the pharynx was measured at 0- to 100-ml cuff volume in 10-ml increments, and for the distal cuff in the esophagus and trachea were measured at 0- to 20-ml cuff volume in 2-ml increments. The proximal cuff volume to form an oropharyngeal seal of 30 cm H2O was determined. In addition, mucosal pressures for the proximal cuff in the pharynx were measured in four awake volunteers with topical anesthesia. Results There was an increase in mucosal pressure in the trachea, esophagus, and pharynx at all cuff locations with increasing volume (all: P < 0.001). Pharyngeal mucosal pressures were highest posteriorly (50-ml cuff volume: 99 +/- 62 cm H2O; 100-ml cuff volume: 255 +/- 161 cm H2O). Esophageal mucosal pressures were highest posteriorly (10-ml cuff volume: 108 +/- 55 cm H2O; 20-ml cuff volume: 269 +/- 133 cm H2O). Tracheal mucosal pressures were highest anteriorly (10-ml cuff volume: 98 +/- 53 cm H2O; 20-ml cuff volume: 236 +/- 139 cm H2O). The proximal cuff volume to obtain an oropharyngeal seal of 30 cm H2O was 47 +/- 12 ml. Pharyngeal mucosal pressures were similar for cadavers and awake volunteers. Conclusion We conclude that mucosal pressures for the esophageal tracheal combitube increase with cuff volume, are highest where the cuff is adjacent to rigid anatomic structures, and potentially exceed mucosal perfusion pressure even when cuff volumes are limited to achieving an oropharyngeal seal of 30 cm H2O.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference25 articles.

Cited by 32 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3