The Iontophoresis of Fentanyl Citrate in Humans

Author:

Ashburn M. A.,Streisand J.,Zhang J.,Love G.,Rowin M.,Niu S.,Kievit J. K.,Kroep J. R.,Mertens M. J.

Abstract

Background Iontophoresis is a method of transdermal administration of ionizable drugs in which the electrically charged components are propelled through the skin by an external electric field. This study was designed to determine whether iontophoresis could be used to deliver clinically significant doses of fentanyl in humans and whether there is a charge-dose relation in the delivery of fentanyl by iontophoresis. Methods Five adult volunteers were tested three times on separate days, once receiving passive treatment of 0.0 mA for 2 h (0 mA.min), iontophoresis 1.0 mA for 2 h (120 mA.min), and iontophoresis 2.0 mA for 2 h (240 mA.min) in an open, randomized, crossover design. Respiratory rate, heart rate, blood pressure, and hemoglobin oxygen saturation were monitored throughout the study. Plasma fentanyl concentrations were measured several times before, during, and after iontophoresis. Plasma fentanyl concentrations were measured by radioimmunoassay. Results No fentanyl was detected after passive (0.0-mA) fentanyl delivery. The following results were obtained for the 1.0- and 2.0-mA deliveries, respectively. Mean times to detectable concentrations of plasma fentanyl were 33 and 19 min; mean times to maximum concentration were 122 and 119 min; maximum concentrations were 0.76 and 1.59 ng/ml (P = 0.010); mean areas under the curve of the plasma fentanyl concentration versus time relation were 233 and 474 ng.ml-1.min (P = 0.003); and mean elimination half-lives were 354 and 413 min (P = 0.326). Only minor adverse side effects related to iontophoresis occurred. However, typical opioid-related effects occurred frequently in the 1.0- and 2.0-mA administration groups. Conclusions Clinically significant doses of fentanyl can be administered by iontophoresis for delivery periods of 2 h. A charge-dose relation exists after administration with currents of 1.0 and 2.0 mA. Future research into the iontophoresis of fentanyl as a method of potent opioid administration is indicated.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference37 articles.

Cited by 69 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Niederfrequente Elektrotherapie;Evidenzbasierte Elektrotherapie;2022

2. Controlled Drug Delivery into and Through Skin;Fundamentals of Drug Delivery;2021-10-26

3. Iontophoretic drug delivery systems;Bioelectronics and Medical Devices;2019

4. Pharmacokinetics and Pharmacology of Drugs Used in Children;A Practice of Anesthesia for Infants and Children;2019

5. Iontophoresis for Therapeutic Drug Delivery and Non-invasive Sampling Applications;Percutaneous Penetration Enhancers Physical Methods in Penetration Enhancement;2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3