Abstract

Background Volatile anesthetics precondition against myocardial infarction, but it is unknown whether this beneficial action is threshold- or dose-dependent. The authors tested the hypothesis that isoflurane decreases myocardial infarct size in a dose-dependent fashion in vivo. Methods Barbiturate-anesthetized dogs (n = 40) were instrumented for measurement of systemic hemodynamics including aortic and left ventricular pressures and rate of increase of left ventricular pressure. Dogs were subjected to a 60-min left anterior descending coronary artery occlusion followed by 3 h of reperfusion and were randomly assigned to receive either 0.0, 0.25, 0.5, 1.0, or 1.25 minimum alveolar concentration (MAC) isoflurane in separate groups. Isoflurane was administered for 30 min and discontinued 30 min before left anterior descending coronary artery occlusion. Results Infarct size (triphenyltetrazolium staining) was 29 +/- 2% of the area at risk in control experiments (0.0 MAC). Isoflurane produced significant (P < 0.05) reductions of infarct size (17 +/- 3, 13 +/- 1, 14 +/- 2, and 11 +/- 1% of the area at risk during 0.25, 0.5, 1.0, and 1.25 MAC, respectively). Infarct size was inversely related to coronary collateral blood flow (radioactive microspheres) in control experiments and during low (0.25 or 0.5 MAC) but not higher concentrations of isoflurane. Isoflurane shifted the linear regression relation between infarct size and collateral perfusion downward (indicating cardioprotection) in a dose-dependent fashion. Conclusions Concentrations of isoflurane as low as 0.25 MAC are sufficient to precondition myocardium against infarction. High concentrations of isoflurane may have greater efficacy to protect myocardium during conditions of low coronary collateral blood flow.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference28 articles.

Cited by 109 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3