Preoxygenation Is More Effective in the 25° Head-up Position Than in the Supine Position in Severely Obese Patients

Author:

Dixon Benjamin J.1,Dixon John B.2,Carden Jennifer R.3,Burn Anthony J.3,Schachter Linda M.4,Playfair Julie M.5,Laurie Cheryl P.5,O’Brien Paul E.6

Affiliation:

1. Advanced Surgical Trainee.

2. Associate Professor, Head of Clinical Research.

3. Consultant Specialist Anaesthetist, Bariatric Surgery.

4. Consultant Specialist Respiratory/Sleep Physician.

5. Research Nurse.

6. Director, and Specialist, Bariatric Surgeon.

Abstract

Background Class III obese patients have altered respiratory mechanics, which are further impaired in the supine position. The authors explored the hypothesis that preoxygenation in the 25 degrees head-up position allows a greater safety margin for induction of anesthesia than the supine position. Methods A randomized controlled trial measured oxygen saturation and the desaturation safety period after 3 min of preoxygenation in 42 consecutive (male:female 13:29) severely obese (body mass index > 40 kg/m) patients who were undergoing laparoscopic adjustable gastric band surgery and were randomly assigned to the supine position or the 25 degrees head-up position. Serial arterial blood gases were taken before and after preoxygenation and 90 s after induction. After induction, ventilation was delayed until blood oxygen saturation reached 92%, and this desaturation safety period was recorded. Results The mean body mass indexes for the supine and 25 degrees head-up groups were 47.3 and 44.9 kg/m, respectively (P = 0.18). The group randomly assigned to the 25 degrees head-up position achieved higher preinduction oxygen tensions (442 +/- 104 vs. 360 +/- 99 mmHg; P = 0.012) and took longer to reach an oxygen saturation of 92% (201 +/- 55 vs. 155 +/- 69 s; P = 0.023). There was a strong positive correlation between the induction oxygen tension achieved and the time to reach an oxygen saturation of 92% (r = 0.51, P = 0.001). There were no adverse events associated with the study. Conclusion Preoxygenation in the 25 degrees head-up position achieves 23% higher oxygen tensions, allowing a clinically significant increase in the desaturation safety period--greater time for intubation and airway control. Induction in the 25 degrees head-up position may provide a greater safety margin for airway control.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference19 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3