Hemodynamic Benefit of Positive End-expiratory Pressure during Acute Descending Aortic Occlusion

Author:

Johnston William E.1,Conroy Brendan P.2,Miller Gregory S.3,Lin Cheng Y.4,Deyo Donald J.3

Affiliation:

1. Professor and James F. Arens Distinguished Chair.

2. Associate Professor.

3. Assistant Professor.

4. Research Associate.

Abstract

Background Acute aortic occlusion in vascular surgery patients abruptly increases arterial resistance and blood pressure, which, in turn, makes subsequent volume expansion during cross-clamp application difficult. The use of vasodilatory drugs or volatile anesthetic agents to attenuate this response may have persistent detrimental effects after clamp removal. Another potential therapy that produces rapid effects on myocardial loading conditions is positive end-expiratory pressure (PEEP). In a porcine model of acute aortic clamping, the hemodynamic consequences of 15 cm H(2)O PEEP with and without plasma volume expansion were studied.(2) Methods Forty anesthetized pigs underwent 30-min occlusion of the abdominal aorta 1 cm above the origin of the celiac artery. Animals were randomly divided into four treatment groups (n = 10 each) to receive 15 cm H(2)O PEEP or zero end-expiratory pressure (ZEEP) with or without plasma volume expansion using 6% hetastarch (10 ml/kg) during cross-clamp application. Mean aortic pressure was measured with a transducer-tipped catheter placed in the ascending aorta; stroke volume was calculated using thermodilution cardiac output. End-expiratory pressure was discontinued upon aortic declamping, and animals were studied over the ensuing 30-min period. Results Aortic occlusion doubled systemic vascular resistance in all groups. Mean aortic blood pressure increased significantly in both ZEEP groups at 1 and 5 min but not in animals treated with 15 cm H(2)O PEEP. The application of PEEP with aortic cross-clamping reduced cardiac output and stroke volume by nearly 50%. Cardiac output and stroke volume increased after volume expansion regardless of end-expiratory pressure. After aortic declamping, aortic blood pressure decreased in all groups but was significantly greater in the PEEP + volume group than in either ZEEP group. Similarly, 5 min after declamping, stroke volume was greatest in the PEEP + volume animals. Conclusions Fifteen cm H(2)O PEEP reduces the hypertensive response to acute aortic occlusion and allows concomitant volume expansion. Consequently, stroke volume and blood pressure are better maintained after clamp removal in PEEP + volume animals. The use of PEEP during acute aortic occlusion in patients may allow rapid control of loading conditions to attenuate systemic hypertension while permitting simultaneous volume expansion.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference33 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3