Brachial Plexus Examination and Localization Using Ultrasound and Electrical Stimulation

Author:

Perlas Anahi1,Chan Vincent W. S.2,Simons Martin3

Affiliation:

1. Resident.

2. Associate Professor, Department of Anesthesia.

3. Assistant Professor, Department of Medical Imaging.

Abstract

Background Current techniques of brachial plexus block are "blind," and nerve localization can be frustrating and time consuming. Previous studies on ultrasound-assisted brachial plexus blocks are mostly performed with scanning probes of 10 MHz or less. The authors tested the usefulness of a state-of-the-art, high-resolution ultrasound probe (up to 12 MHz) in identifying the brachial plexus in five locations of the upper extremity and in guiding needle advancement to target before nerve stimulation. Methods In this prospective observational study, 15 volunteers underwent brachial plexus examination using an L12-L5 MHz probe and a Philips-ATL 5000 ultrasound unit in the interscalene, supraclavicular, infraclavicular, axillary, and midhumeral regions. Thereafter, an insulated block needle was advanced under direct ultrasound guidance to target nerves before confirmation by electrical nerve stimulation in five volunteers in each of the interscalene, supraclavicular, and axillary regions. The quality of brachial plexus images, anatomic variations, and the technique of needle advancement for nerve localization were recorded. Results The brachial plexus components were successfully identified in the transverse view as round to oval hypoechoic structures with small internal punctuate echos in all regions examined except the infraclavicular area (visualized in 27% of the cases). The authors' technique of advancing the needle in-line with the ultrasound beam allowed moment-by-moment observation of the needle shaft and tip movement at the time of nerve localization. Hypoechoic structures were stimulated electrically and confirmed to be nerves. Conclusions These preliminary data show that the high-resolution L12-L5 probe provides good quality brachial plexus ultrasound images in the superficial locations i.e., the interscalene, supraclavicular, axillary, and midhumeral regions. The needle technique described here for ultrasound-assisted nerve localization provides real-time guidance and is potentially valuable for brachial plexus blocks.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference27 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3