Transcutaneous Fluorescence Dilution Cardiac Output and Circulating Blood Volume during Hemorrhagic Hypovolemia

Author:

Maarek Jean-Michel I.1,Holschneider Daniel P.2,Yang Jun3,Pniak Sarah N.4,Rubinstein Eduardo H.5

Affiliation:

1. Senior Lecturer.

2. Associate Professor, Departments of Cell and Neurobiology, Psychiatry, and Neurology.

3. Research Associate, Department of Psychiatry, University of Southern California.

4. Research Assistant, Department of Biomedical Engineering.

5. Professor, Department of Anesthesiology and Physiology, University of California, Los Angeles, California.

Abstract

Background Cardiac output and circulating blood volume are important parameters for assessing cardiac function in the intensive care setting and during major surgeries. The authors tested in an animal model of hemorrhagic hypovolemia the feasibility of measuring these parameters simultaneously by transcutaneous fluorescence monitoring of an intravenous bolus injection of indocyanine green. Methods Fluorescence dilution cardiac output was measured in seven anesthetized rabbits and compared to thermodilution cardiac output. The optical probe used to excite the indocyanine green fluorescence was in contact with the skin above the ear artery. Local heating enhanced blood perfusion of the measurement site. Cardiac output was measured during baseline conditions, during hemorrhagic hypovolemia, and after partial restoration of the blood volume with reinfused blood. Estimates of the circulating blood volume were simultaneously obtained from the analysis of the fluorescence dilution traces. Results Cardiac output measured by fluorescence dilution (thermodilution) averaged 455 +/- 16 (450 +/- 13) ml/min in baseline conditions and 323 +/- 15 (330 +/- 13) ml/min during hypovolemia. Fluorescence dilution cardiac output was linearly related to thermodilution cardiac output (slope = 1.13 +/- 0.05, ordinate = -50 +/- 19 ml/min, R = 0.92). Interanimal differences explained most of the variance between cardiac output estimates obtained with the two techniques. Circulating blood volume decreased from 204 +/- 5 ml in baseline conditions to 174 +/- 8 ml after bleeding and reflected blood volume changes in this acute bleeding-reinfusion model. Conclusions The study extends the applicability of the fluorescence dilution technique for cardiac output measurement to hypovolemic conditions and demonstrates its ability to produce accurate estimates of the circulating blood volume in experimental animals.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference39 articles.

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3