Changes in the Position of Epidural Catheters Associated with Patient Movement

Author:

Hamilton Catherine L.,Riley Edward T.,Cohen Sheila E.

Abstract

Background Epidural catheter movement has been noted with change of patient position and can result in inadequate anesthesia. This study was designed to measure movement and to develop a technique that minimizes catheter displacement. Methods In 255 parturients requesting epidural anesthesia for labor or cesarean section, a multiorificed lumbar epidural catheter was inserted with the patient in the sitting flexed position. The distance to the epidural space, length of catheter inserted, and amount of catheter position change as the patient moved from the sitting flexed to sitting upright and then to the lateral decubitus position were measured before the catheter was secured to the skin. Adequacy of analgesia, the need for catheter manipulation, and whether the patient was considered obese were noted. Data were grouped according to body mass index (BMI): < 25, 25-30, and > 30 kg/m2. Results The groups did not differ with respect to the length of catheter initially inserted or changes in catheter position between initial taping and removal. The distance to the epidural space differed significantly among the groups, increasing with greater BMI. Catheters frequently appeared to be drawn inward with position change from the sitting flexed to lateral decubitus position, with the greatest change seen in patients with BMI > 30. Only nine catheters were associated with inadequate analgesia, four of which were replaced. No analgesic failures occurred in the BMI > 30 group. In patients judged by the anesthesiologist to be obese or to have an obese back, BMI was greater, and distance to the epidural space and the magnitude of catheter movement with position change were greater than in those who were not obese. Conclusions Epidural catheters moved a clinically significant amount with reference to the skin in all BMI groups as patients changed position. If catheters had been secured to the skin before position change, many would have been pulled partially out of the epidural space. To minimize the risk of catheter displacement, particularly in obese patients, we recommend that multiorificed catheters be inserted at least 4 cm into the epidural space and that patients assume the sitting upright or lateral position before securing the catheter to the skin.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference16 articles.

Cited by 109 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Anesthetic challenges of pregnant obesity women;Best Practice & Research Clinical Obstetrics & Gynaecology;2023-12

2. Epidural catheter migration in non-obstetric adult surgical patients: A prospective, observational, cohort study;Indian Journal of Anaesthesia;2023-06

3. Regional anaesthesia for caesarean sections;ANASTH INTENSIVMED;2023

4. Epidural catheter kinking – An appalling experience;Journal of Anaesthesiology Clinical Pharmacology;2023

5. Relief of Labor Pain by Regional Analgesia/Anesthesia;Datta's Obstetric Anesthesia Handbook;2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3