Relative Analgesic Potencies of Levobupivacaine and Ropivacaine for Epidural Analgesia in Labor

Author:

Polley Linda S.1,Columb Malachy O.2,Naughton Norah N.3,Wagner Deborah S.4,van de Ven Cosmas J. M.5,Goralski Kathryn H.6

Affiliation:

1. Clinical Associate Professor.

2. Consultant in Anaesthesia and Intensive Medicine, South Manchester University Hospitals’ Trust, Wythenshawe, United Kingdom.

3. Clinical Associate Professor, Division of Obstetric Anesthesiology.

4. Clinical Assistant Professor, University of Michigan Health System, Ann Arbor, Michigan.

5. Clinical Associate Professor, Division of Maternal-Fetal Medicine.

6. Resident, Department of Obstetrics and Gynecology.

Abstract

Background The minimum local analgesic concentration has been defined as the median effective local analgesic concentration (EC50) in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to assess the relative analgesic potencies of epidural levobupivacaine and ropivacaine by determination of their respective minimum local analgesic concentrations. Methods Parturients at 7 cm of cervical dilation or less who requested epidural analgesia were allocated to one of two groups in this double-blind, randomized, prospective study. After lumbar epidural catheter placement, 20 ml of the test solution was given: levobupivacaine (n = 35) or ropivacaine (n = 35). The concentration of local anesthetic was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scale scores, with 10 mm or less within 30 min defined as effective. An effective result directed a 0.01% wt/vol decrement for the next patient. An ineffective result directed a 0.01% wt/vol increment. Results Of 105 women enrolled, 35 were excluded, leaving 70 for analysis. The minimum local analgesic concentration of levobupivacaine was 0.087% wt/vol (95% CI, 0.081-0.094%), and the minimum local analgesic concentration of ropivacaine was 0.089% wt/vol (95% CI, 0.075-0.103%). Levobupivacaine and ropivacaine were of similar potency with a ropivacaine:levobupivacaine potency ratio of 0.98 (95% CI, 0.80-1.20). No difference in motor effects was observed. Conclusions This study demonstrated that levobupivacaine and ropivacaine are of similar potency for epidural analgesia in the first stage of labor.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference15 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3