Abstract

Background Monitoring left ventricular preload is critical to achieve adequate fluid resuscitation in patients with hypotension and sepsis. This prospective study tested the correlation of the pulmonary artery occlusion pressure, the left ventricular end-diastolic area index measured by transesophageal echocardiography, the arterial systolic pressure variation (the difference between maximal and minimal systolic blood pressure values during one mechanical breath), and its delta down (dDown) component (= apneic - minimum systolic blood pressure) with the response of cardiac output to volume expansion during sepsis. Methods Preload parameters were measured at baseline and during graded volume expansion (increments of 500 ml) in 15 patients with sepsis-induced hypotension who required mechanical ventilation. Each volume-loading step (VLS) was classified as a responder (increase in stroke volume index > or = 15%) or a nonresponder. Successive VLSs were performed until a nonresponder VLS was obtained. Results Thirty-five VLSs (21 responders) were performed. Fluid loading caused an overall significant increase in pulmonary artery occlusion pressure and end-diastolic area index, and a significant decrease in systolic pressure variation and delta down (P < 0.01). There was a significant difference between responder and nonresponder VLSs in end-diastolic area index, systolic pressure variation, and dDown, but not in pulmonary artery occlusion pressure. Receiver-operator curve analysis showed that dDown was a more accurate indicator of the response of stroke volume index to volume loading than end-diastolic area index and pulmonary artery occlusion pressure. A dDown component of more than 5 mmHg indicated that the stroke volume index would increase in response to a subsequent fluid challenge (positive and negative predictive values: 95% and 93%, respectively). Conclusion The dDown component of the systolic pressure variation is a sensitive indicator of the response of cardiac output to volume infusion in patient with sepsis-induced hypotension who require mechanical ventilation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference18 articles.

Cited by 471 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3