Blood Volume Measurement at the Bedside Using ICG Pulse Spectrophometry

Author:

Haruna Masaki,Kumon Keiji,Yahagi Naoki,Watanabe Yasuhiko,Ishida Yoshio,Kobayashi Naoki,Aoyagi Takuo

Abstract

Background In the treatment of critically ill patients, blood volume (BV) measurement requires injection of some tracer substance and subsequent blood sampling to analyze the tracer concentration. To obviate both the sampling and laboratory analysis, techniques of pulse oximetry have been adapted to the noninvasive optical measurement in the patient's nose or finger of the arterial concentration of an injectable dye. Methods The authors report the clinical accuracy of a new noninvasive bedside BV measurement test that uses pulse spectrophotometry (the pulse method). The device detects pulsatile changes of tissue optical density of a nostril or a finger spanned by a probe emitting two infrared wavelengths (805 and 890 nm). After a peripheral or central intravenous injection of indocyanine green, the arterial dye concentration is continuously computed by reference to the previously measured blood hemoglobin concentration. Three types of tests of its accuracy are described here. Results In 10 healthy volunteers, the authors compared BV determined by the pulse method with an (131)I-labeled human serum albumin method. Three subject data sets were excluded because of motion artifact, a low signal:noise ratio, or both. For the other seven volunteers, the bias+/-SD of pulse spectrophotometric BV values were 0.20+/-0.24 l (or 4.2+/-4.9%) for the nose probe and 0.34+/-0.31 l (or 7.3+/-6.9%) for the finger probe, with a mean BV of 5 l. In 30 patients who underwent cardiac surgery, the pulse method was compared with a standard indocyanine green method using intermittent blood sampling. In three patients, the BV could not be determined by the pulse method because of motion artifact, low signal:noise ratio, or both. In 27 patients, the bias+/-SD of the BV by the pulse method was -0.23+/-0.37 l (-5.3+/-8.7%) for the nose and -0.25+/-0.5 l (-4.2+/-8.4%) for the finger. Patient BV ranged from 2.51 to 7.13 l (mean, 4.48 l). In 10 additional patients before cardiac surgery, BV was measured by the pulse method before and shortly after removal of 400 ml blood. The pulse method recorded a decrease of BV of 480+/-114 mL Three days after venesection, the mean BV was 117+/-159 ml less than the predonation control. Conclusions In most patients, the pulse method provides bedside measurement of BV without blood sampling (except for hemoglobin determination), with an estimated error less than 10%. In 10-30% of tests the method failed because of motion distortion of the record during the 10-min data collection period or because of insufficient pulse amplitude in the test tissue.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference22 articles.

Cited by 94 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3