Endotracheal Cardiac Output Monitor

Author:

Wallace Arthur W.1,Salahieh Ali2,Lawrence Andrew3,Spector Ken4,Owens Chris5,Alonso David2

Affiliation:

1. Assistant Professor in Residence, Department of Anesthesiology, University of California–San Francisco.

2. Research Fellow, Department of Anesthesiology, University of California–San Francisco.

3. Senior Program Manager, Rivertek Medical Systems.

4. Program Manager, ACT Medical.

5. Program Manager, Imagyn Medical Technologies.

Abstract

Background The endotracheal cardiac output monitor (ECOM) is a new device that uses an endotracheal tube with multiple electrodes to measure cardiac output (CO). It measures the changes in electrical impedance caused by pulsatile blood flow in the aorta. The system was tested for safety and efficacy in 10 swine. Methods Swine (60-80 kg) were chronically instrumented with a transit time flow probe on the ascending aorta and vascular occluders on the vena cava and pulmonary artery. After a minimum recovery of 4 days, the animals were anesthetized and intubated with an ECOM endotracheal tube. CO measurements from the ECOM system were compared to transit time flow probe measurements using linear regression and Bland-Altman analysis. Three different inotropic states were studied: (1) baseline; (2) increased (dobutamine); and (3) decreased (esmolol). CO was changed at each inotropic state by impeding left ventricular filling with the vena cava or pulmonary artery occluders. CO values between 0 and 15 l/min were studied. Pigs were studied for 24 h consecutively. Results There was no deterioration of the impedance signal with time and no tracheal injury from the ECOM electrodes. There is a linear relationship between the ECOM and transit time flow probe CO between 0 and 15 l/min (slope = 0.94; intercept = 0.15 l/min; R2= 0.77). The mean difference between the two measures (bias) is 0.15 l/min and the SD is 1.34 l/min. The limits of agreement are -2.53 to 2.82 l/min. Conclusion Endotracheal CO monitor is a promising technology that needs further evaluation in clinical trials.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference35 articles.

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Anesthesia Patient Monitoring 2050;Anesthesia & Analgesia;2024-01-12

2. Hemodynamic Monitoring in Thoracic Surgical Patients;Cohen's Comprehensive Thoracic Anesthesia;2022

3. Monitoring Cardiac Output Using Impedance Cardiography: A Technical Review;2021 IEEE International Conference on Intelligent Systems, Smart and Green Technologies (ICISSGT);2021-11

4. Perioperative Hemodynamic Monitoring;Anesthesiology Clinics;2021-09

5. Current Practice Issues in Thoracic Anesthesia;Anesthesia & Analgesia;2021-08-23

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3