An Evaluation of Transcutaneous Carbon Dioxide Partial Pressure Monitoring during Apnea Testing in Brain-dead Patients

Author:

Vivien Benoîit1,Marmion Frédéric1,Roche Sabine1,Devilliers Catherine2,Langeron Olivier1,Coriat Pierre3,Riou Bruno4

Affiliation:

1. Assistant Professor, Department of Anesthesiology.

2. Staff Biologist, Department of Emergency Biology.

3. Professor of Anesthesiology and Chairman, Department of Anesthesiology and Critical Care.

4. Professor of Anesthesiology and Chairman, Department of Emergency Medicine and Surgery, Centre Hospitalier Universitaire Pitié-Salpîetrière.

Abstract

Background Diagnosis of brain death usually requires an arterial carbon dioxide partial pressure (Paco2) of 60 mmHg during the apnea test, but the increase in Paco2 is unpredictable. The authors evaluated whether transcutaneous carbon dioxide partial pressure (Ptcco2) monitoring during apnea test can predict that a Paco2 of 60 mmHg has been reached. Methods The authors compared Ptcco2 measured with a transcutaneous ear sensor (V-Sign Sensor, Sentec Digital Monitoring System; SENTEC-AG, Therwil, Switzerland) and Paco2 obtained from arterial blood gas measurements in 32 clinically brain-dead patients. Results In the first 20 patients, the mean Paco2-Ptcco2 gradient was 0.7 +/- 3.6 mmHg at baseline and 8.7 +/- 7.1 mmHg after 20 min of apnea. Using receiver operating characteristic curve analysis (area under the curve: 0.983 +/- 0.013), the best threshold value of Ptcco2 to predict that a Paco2 of 60 mmHg had been reached was 60 mmHg (positive predictive value: 1.00 [0.93-1.00]). In the following 12 patients investigated with use of this Ptcco2 target value of 60 mmHg, the mean duration of the apnea test (11 +/- 4 vs. 20 +/- 0 min; P < 0.001), hypercapnia (74.0 +/- 4.9 vs. 98.3 +/- 20.0 mmHg; P < 0.001), acidosis (pH: 7.18 +/- 0.06 vs. 7.11 +/- 0.08; P < 0.001), and decrease in arterial oxygen partial pressure (-47 +/- 44 vs. -95 +/- 89; P < 0.05) at the end of the test were reduced as compared with the 20-min apnea test group. Conclusion During the apnea test in brain-dead patients, a Ptcco2 of 60 mmHg accurately predicts that a Paco2 of 60 mmHg has been reached. This may allow a reduction in the duration of the apnea test and consecutively limit occurrence of complications.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference32 articles.

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3