The Glottic Aperture Seal Airway

Author:

Benumof Jonathan L.

Abstract

Background None of the presently used airway devices are ideal regarding ease of insertion, alignment with the laryngeal inlet, and provision of a high-pressure seal from the environment. The purpose of this study was to determine, in awake volunteers, the performance of a new ventilatory device, the glottic aperture seal airway, regarding ease of insertion, alignment with the laryngeal inlet, and forced exhalation seal pressure (PFES). Methods The glottic aperture seal airway consists of a curved tubular component that ends in the middle of an elliptical foam cushion glottic component. The posterior surface of the foam has a curved flexible plastic backing, which imparts a 60 degree angle between the proximal half and the distal half of the foam cushion. When the glottic aperture seal airway is properly in situ in a supine patient, the proximal half of the foam cushion is opposite the laryngeal inlet. The posterior surface of the plastic backing has a balloon attached to it. Inflation of the balloon presses the ventilation hole and foam cushion up against the laryngeal inlet, thereby creating a seal from the environment. Using the laryngeal mask airway as a control device, the glottic aperture seal airway was tested for time and ease of insertion, fiberoptic alignment with the laryngeal inlet, and PFES in 18 lightly sedated and locally anesthetized volunteers. Results The glottic aperture seal and laryngeal mask airways were inserted with equal ease and speed. The fiberoptic alignment with the larynx was excellent for both the glottic aperture seal and laryngeal mask airways. In all volunteers, the mean +/- SD PFES values at 0-, 10-, 20-, 30-, and 40-ml balloon inflation volumes of the glottic aperture seal airway were 23.4 +/- 11.8, 29.6 +/- 12.4, 42.7 +/- 12.5, 56.9 +/- 5.6, and 60 +/- 0 cm H2O, respectively; the PFES at > or = 20 ml balloon inflation volume of the glottic aperture seal airway was significantly greater than with the laryngeal mask airway (19.4 +/- 6.7 cm H2O, P < 0.01). A PFES of > or =60 cm H2O was achieved with the glottic aperture seal airway in all volunteers (n = 2 at 10 ml, n = 3 at 20 ml, n = 9 at 30 ml, and n = 4 at 40 ml). The glottic aperture seal airway did not cause any trauma. Conclusion In awake volunteers, the glottic aperture seal and laryngeal mask airways were equally easy to insert and position. The glottic aperture seal airway was capable of achieving a higher PFES than the laryngeal mask airway.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference1 articles.

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Safety and clinical usefulness of supraglottic airway device;Journal of the Korean Medical Association;2015

2. Complications of Managing the Airway;Benumof and Hagberg's Airway Management;2013

3. Complications of Managing the Airway;Benumof's Airway Management;2007

4. A Proposed Classification and Scoring System for Supraglottic Sealing Airways: A Brief Review;Anesthesia & Analgesia;2004-11

5. Is It Unethical to Use the Combitube in Elective Surgery Patients?;Anesthesiology;2003-04-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3