Lightwand Tracheal Intubation with and without Muscle Relaxation

Author:

Massó Eva1,Sabaté Sergi2,Hinojosa Marta1,Vila Pere1,Canet Jaume3,Langeron Olivier4

Affiliation:

1. Staff Anesthesiologist.

2. Staff Anesthesiologist, Department of Anesthesiology, Fundación Puigvert.

3. Chairman, Department of Anesthesiology, Hospital Universitari Germans Trias i Pujol.

4. Assistant Professor, Department of Anesthesiology and Critical Care, Centre Hospitalo-universitaire Pitié-Salpêtrière.

Abstract

Background Lightwand tracheal intubation is a suitable technique for patients who are difficult to intubate but who are receiving effective ventilation. The effect of muscle relaxants on the efficacy of lightwand intubation has not yet been evaluated. The authors conducted a prospective, double-blind, placebo-controlled study to assess the effectiveness and incidence of complications of lightwand tracheal intubation performed during general anesthesia with and without the use of a muscle relaxant in patients with apparently normal airway anatomy. Methods One hundred seventy-six patients who required orotracheal intubation were prospectively included. Anesthesia was administered using propofol (2 mg/kg, then 3 mg . kg (-1). h(-1)) and remifentanil (1 microg/kg, then 0.3 microg . kg(-1) . min(-1)). Patients were randomly assigned to one of two groups (n = 88 for each) to receive rocuronium 0.6 mg/kg or saline intravenously. Lightwand orotracheal intubation (Trachlight; Laerdal Medical Inc., Armonk, NY) was attempted after 3 min. The authors recorded the number of successful intubations, the number of attempts and their duration, and events during the procedure. Results The failure rate of lightwand intubation was 12% in the placebo group and 2% in the rocuronium group (P = 0.021). Patients in the placebo group received more multiple intubation attempts (P < 0.001), required a greater intubation time (77 +/- 65 vs. 52 +/- 31 s; P = 0.002) and experienced a greater incidence of events during intubation (61 vs. 0%; P < 0.001) than patients in the rocuronium group. Conclusions The use of muscle relaxants in patients with apparently normal airways is associated with a lower failure rate, decreased intubation time, and fewer attempts when performing lightwand orotracheal intubation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference26 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3