Effects of Peak Inspiratory Flow on Development of Ventilator-induced Lung Injury in Rabbits

Author:

Maeda Yoshiko1,Fujino Yuji2,Uchiyama Akinori3,Matsuura Nariaki4,Mashimo Takashi5,Nishimura Masaji2

Affiliation:

1. Graduate student.

2. Associate Professor.

3. Assistant Professor, Intensive Care Unit, Osaka University Hospital, Suita, Osaka, Japan.

4. Professor, Department of Pathology, School of Allied Health Sciences, Osaka University, Suita, Osaka, Japan.

5. Professor, Department of Anesthesiology, Osaka University Medical School, Suita, Osaka, Japan.

Abstract

Background A lung-protecting strategy is essential when ventilating acute lung injury/acute respiratory distress syndrome patients. Current emphasis is on limiting inspiratory pressure and volume. This study was designed to investigate the effect of peak inspiratory flow on lung injury. Methods Twenty-four rabbits were anesthetized, tracheostomized, ventilated with a Siemens Servo 300, and randomly assigned to three groups as follows: 1) the pressure regulated volume control group received pressure-regulated volume control mode with inspiratory time set at 20% of total cycle time, 2) the volume control with 20% inspiratory time group received volume-control mode with inspiratory time of 20% of total cycle time, and 3) the volume control with 50% inspiratory time group received volume-control mode with inspiratory time of 50% of total cycle time. Tidal volume was 30 ml/kg, respiratory rate was 20 breaths/min, and positive end-expiratory pressure was 0 cm H2O. After 6 h mechanical ventilation, the lungs were removed for histologic examination. Results When mechanical ventilation started, peak inspiratory flow was 28.8 +/- 1.4 l/min in the pressure regulated volume control group, 7.5 +/- 0.5 l/min in the volume control with 20% inspiratory time group, and 2.6 +/- 0.3 l/min in the volume control with 50% inspiratory time group. Plateau pressure did not differ significantly among the groups. Gradually during 6 h, Pao2 in the pressure regulated volume control group decreased from 688 +/- 39 to a significantly lower 304 +/- 199 mm Hg (P < 0.05) (mean +/- SD). The static compliance of the respiratory system for the pressure regulated volume control group also ended significantly lower after 6 h (P < 0.05). Wet to dry ratio for the pressure regulated volume control group was larger than for other groups (P < 0.05). Macroscopically and histologically, the lungs of the pressure regulated volume control group showed more injury than the other groups. Conclusion When an injurious tidal volume is delivered, the deterioration in gas exchange and respiratory mechanics, and lung injury appear to be marked at a high peak inspiratory flow.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference23 articles.