Evaluation of a New Point-of-care Celite-activated Clotting Time Analyzer in Different Clinical Settings

Author:

Paniccia Rita1,Fedi Sandra1,Carbonetto Fiorella2,Noferi Daniela2,Conti Paolo3,Bandinelli Brunella1,Giusti Betti1,Evangelisti Lucia1,Pretelli Paola2,Palmarini Mara F.G.2,Abbate Rosanna1,Prisco Domenico1

Affiliation:

1. Senior Researcher, Technician, Researcher, Professor, Associate Professor, Dipartimento di Area Critica Medico-Chirurgica, Sezione di Clinica Medica Generale e Cliniche Specialistiche, Centro di Riferimento Regionale per la Trombosi. University of Florence, Florence, Italy.

2. Research Fellow, Unità Operativa di Anestesiologia e Rianimazione 1.

3. Research Fellow, Centro Emodialisi, Azienda Ospedaliera Careggi, Florence, Italy.

Abstract

Background Activated clotting time (ACT) is used to monitor heparin therapy during cardiopulmonary bypass, interventional cardiology, and hemodialysis. Traditionally, ACT is performed by use of the Hemochron system. Recently, a new device, the i-STAT system, has been introduced to measure ACT. The aim of this study was to correlate the performances of these two systems and to compare ACT values with heparin levels. Methods One hundred sixty-five samples from 29 patients undergoing cardiopulmonary bypass or hemodialysis were assayed in duplicate with two Hemochron and two i-STAT devices. Heparin levels were determined by anti-factor Xa assay. Results The Hemochron ACT ranged from 88 to 1,028 s, and the i-STAT ACT ranged from 80 to 786 s. Heparin plasma levels ranged from 0.01 to 10.8 U/mL. Bland-Altman analysis showed a mean difference between the two methods of 24 +/- 101 s. Strong relationships between anti-factor Xa activity and Hemochron ACTs (r2 = 0.69, P < 0.001) and i-STAT ACTs (r2 = 0.79, P < 0.001) were observed. During cardiac surgery, significant correlations were found: Hemochron, r2 = 0.61, P < 0.001 and i-STAT, r2 = 0.74, P < 0.001. During hemodialysis, relationships between anti-factor Xa activity and ACTs were found: Hemochron, r2 = 0.62, P < 0.001 and i-STAT, r2 = 0.55, P < 0.001. Conclusions During cardiopulmonary bypass procedure and hemodialysis, i-STAT provides measurements of clotting time quite similar to Hemochron ACT, which were significantly correlated with heparin levels.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference31 articles.

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3