Narcotrend Monitoring Allows Faster Emergence and a Reduction of Drug Consumption in Propofol–Remifentanil Anesthesia

Author:

Kreuer Sascha1,Biedler Andreas2,Larsen Reinhard3,Altmann Simone4,Wilhelm Wolfram5

Affiliation:

1. Resident in Anesthesiology.

2. Staff Anesthesiologist.

3. Professor and Director.

4. Research Fellow.

5. Privatdozent and Staff Anesthesiologist.

Abstract

Background The Narcotrend is a new electroencephalographic monitor designed to measure depth of anesthesia, based on a six-letter classification from A (awake) to F (increasing burst suppression) including 14 substages. This study was designed to investigate the impact of Narcotrend monitoring on recovery times and propofol consumption in comparison to Bispectral Index (BIS) monitoring or standard anesthetic practice. Methods With institutional review board approval and written informed consent, 120 adult patients scheduled to undergo minor orthopedic surgery were randomized to receive a propofol-remifentanil anesthetic controlled by Narcotrend, by BIS(R), or solely by clinical parameters. Anesthesia was induced with 0.4 micro x kg-1 x min-1 remifentanil and a propofol target-controlled infusion at 3.5 microg/ml. After intubation, remifentanil was reduced to 0.2 micro x kg-1 x min-1, whereas the propofol infusion was adjusted according to clinical parameters or to the following target values: during maintenance to D(0) (Narcotrend) or 50 (BIS); 15 min before the end of surgery to C(1) (Narcotrend) or 60 (BIS). Recovery times were recorded by a blinded investigator, and average normalized propofol consumption was calculated from induction and maintenance doses. Results The groups were comparable for demographic data, duration of anesthesia, and mean remifentanil dosages. Compared with standard practice, patients with Narcotrend or BIS monitoring needed significantly less propofol (standard practice, 6.8 +/- 1.2 mg x kg-1 x h-1 vs. Narcotrend, 4.5 +/- 1.1 mg x kg-1 x h-1 or BIS(R), 4.8 +/- 1.0 mg x kg-1 x h-1; P < 0.001), opened their eyes earlier (9.3 +/- 5.2 vs. 3.4 +/- 2.2 or 3.5 +/- 2.9 min), and were extubated sooner (9.7 +/- 5.3 vs. 3.7 +/- 2.2 or 4.1 +/- 2.9 min). Conclusions The results indicate that Narcotrend and BIS monitoring are equally effective to facilitate a significant reduction of recovery times and propofol consumption when used for guidance of propofol titration during a propofol-remifentanil anesthetic.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference30 articles.

Cited by 164 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3