Mivacurium Arteriovenous Gradient during Steady State Infusion in Anesthetized Patients

Author:

Ezzine Samia1,Donati François2,Varin France3

Affiliation:

1. Ph.D. Student, Faculté de Pharmacie.

2. Professor, Département d'anesthésie, Faculté de Médecine.

3. Professor, Faculté de Pharmacie.

Abstract

Background Mivacurium and isomers undergo rapid hydrolysis by plasma cholinesterase. As this enzyme is largely distributed, it cannot be excluded that these isomers might undergo peripheral elimination. This hypothesis was investigated in patients by measuring the difference between arterial and venous concentrations under a constant-rate continuous infusion of mivacurium. Methods During propofol-remifentanil anesthesia, eight adult consenting patients received an intravenous bolus dose of 0.2 mg/kg mivacurium, followed by a constant infusion (3, 5, or 7 microg. kg. min ) into the brachial vein. One hour after starting the infusion, arterial (radial artery) and venous (contralateral brachial vein) blood samples were drawn simultaneously at 15-min intervals for 45 min. Mivacurium isomers and metabolite plasma concentrations were determined by stereospecific high-performance liquid chromatography. Using the corresponding arterial and venous concentrations, the tissue extraction coefficient as well as total body clearance were calculated. Results During steady state conditions, the venous concentrations of the and isomers were 34 +/- 13% and 42 +/- 11% (mean +/- SD) lower than the corresponding arterial concentrations (P < 0.05), respectively. For the isomer, the difference between venous and arterial concentrations was 3 +/- 4% (P = 0.063). Total body clearances of the and isomers were greater when based on venous sampling (P < 0.05). Conclusion Pharmacokinetic parameters derived from a constant infusion of mivacurium depend heavily on the sampling site (arterial or venous) for the rapidly hydrolyzed isomers. These results strongly suggest a significant metabolism of mivacurium within muscle tissue that may account for the large interpatient variability in response to mivacurium.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference34 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3