Effect of Intravenous versus  Epidural Fentanyl on the Minimum Local Analgesic Concentration of Epidural Bupivacaine in Labor

Author:

Polley Linda S.1,Columb Malachy O.2,Naughton Norah N.1,Wagner Deborah S.3,Dorantes Deanna M.4,van de Ven Cosmas J. M.5

Affiliation:

1. Assistant Professor, Division of Obstetric Anesthesiology, University of Michigan Health System, Ann Arbor, Michigan.

2. Consultant in Anaesthesia and Intensive Medicine, South Manchester University Hospital, Withington, United Kingdom.

3. Clinical Instructor, University of Michigan Health System, Ann Arbor, Michigan.

4. Lecturer, Division of Obstetric Anesthesiology, University of Michigan Health System, Ann Arbor, Michigan.

5. Assistant Professor, Division of Maternal-Fetal Medicine, University of Michigan Health System, Ann Arbor, Michigan.

Abstract

Background The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration (EC50) in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the relative local anesthetic sparing efficacies of intravenous and epidural fentanyl by comparison of their effects on the MLAC of bupivacaine. Methods In this double-blind, randomized, prospective study, 84 parturients at < or = 7-cm cervical dilation who requested epidural analgesia were allocated to one of two groups. After lumbar epidural catheter placement, 20 ml bupivacaine (n = 44) or bupivacaine with 3 microg/ml (60 microg) fentanyl (n = 40) was administered. The plain bupivacaine group then received 60 microg intravenous fentanyl. The bupivacaine-fentanyl group received intravenous saline. The concentration of bupivacaine was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores, with < or = 10 mm within 30 min define as effective. Results The MLAC of bupivacaine-intravenous fentanyl was 0.064% wt/vol (95% confidence interval, 0.049-0.080), and the MLAC of bupivacaine-epidural fentanyl was 0.034% wt/vol (95% confidence interval, 0.017-0.050). Epidural fentanyl significantly increased the analgesic potency of bupivacaine by a factor of 1.88 (95% confidence interval, 1.09-3.67) compared with intravenous fentanyl. The epidural fentanyl group demonstrated significantly higher dermatomal spread (P = 0.0064) and increased pruritus (P = 0. 01). Conclusions Epidural fentanyl significantly reduced the MLAC of bupivacaine when compared with intravenous fentanyl for the parturients in this study. The significantly enhanced local anesthetic sparing, dermatomal level, and pruritus with epidural fentanyl suggest a primarily spinal site of action.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference29 articles.

Cited by 53 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3