Prospective, Randomized Trial Comparing General with Spinal Anesthesia for Cesarean Delivery in Preeclamptic Patients with a Nonreassuring Fetal Heart Trace

Author:

Dyer Robert A.1,Els Ilse2,Farbas Josef3,Torr Gregory J.4,Schoeman Leann K.5,James Michael F.6

Affiliation:

1. Senior Specialist Anesthesiologist.

2. Specialist Neonatologist, Department of Pediatrics.

3. Senior Resident.

4. Specialist Anesthesiologist.

5. Specialist Obstetrician and Gynecologist, Department of Obstetrics and Gynecology, University of Cape Town and New Groote Schuur Hospital, Cape Town, South Africa.

6. Professor and Head, Department of Anesthesia.

Abstract

Background There are no randomized studies on neonatal outcome after spinal versus general anesthesia for cesarean delivery in preeclamptic patients with a nonreassuring fetal heart trace. This study examined both markers of neonatal hypoxia and maternal hemodynamics. Methods Seventy patients were randomized to general (n = 35) or spinal anesthesia (n = 35). The general anesthesia group received thiopentone, magnesium sulfate, and suxamethonium intravenously before intubation, followed by 50% nitrous oxide in oxygen, 0.75-1.5% isoflurane, and morphine after delivery. The target end-tidal partial pressure of carbon dioxide (Pco2) was 30-34 mmHg. The spinal anesthesia group received 1.8 ml hyperbaric bupivacaine plus 10 microg fentanyl at the L3-L4 interspace. Heart rate and blood pressure were measured at specific time points. Hypotension was treated with ephedrine. Maternal arterial and neonatal umbilical arterial blood gas samples were taken at delivery. Resuscitation requirements were recorded. Results In both groups, hemodynamic measures remained within acceptable limits. Spinal anesthesia patients required more ephedrine (13.7 vs. 2.7 mg). Maternal Paco2 was lower in the spinal group (28.9 vs. 32.4 mmHg). One-minute Apgar scores were lower after general anesthesia. Base deficit was greater (7.13 vs. 4.68 mEq/l) and neonatal umbilical arterial pH was lower (7.20 vs. 7.23) after spinal anesthesia. Post hoc analysis showed that if maternal diastolic blood pressure on admission was greater than 110 mmHg, neonatal umbilical arterial base deficit was greater after spinal anesthesia. There was no difference in the number of patients with Apgar scores less than 7 at 1 or 5 min or umbilical arterial pH less than 7.2 or in the requirements for resuscitation. Conclusions In preeclamptic patients with a nonreassuring fetal heart trace, spinal anesthesia for cesarean delivery was associated with a greater mean neonatal umbilical arterial base deficit and a lower median umbilical arterial pH. The clinical significance remains to be established. Maternal hemodynamics were similar and acceptable with either anesthetic technique.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference27 articles.

Cited by 100 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3