Affiliation:
1. Research Assistant, Department of Biomedical Engineering.
2. Assistant Professor, Department of Anesthesia and Institute for Medicine and Engineering.
Abstract
Background
It is not readily obvious whether an intravascular bubble will grow or shrink in a particular tissue bed. This depends on the constituent gases initially present in the bubble, the surrounding tissue, and the delivered gas admixture. The authors used a computational model based on the physics of gas exchange to predict cerebrovascular embolism behavior during xenon anesthesia.
Methods
The authors estimated values of gas transport parameters missing from the literature. The computational model was used with those parameters to predict bubble size over time for a range of temperatures (18 degrees -39 degrees C) used during extracorporeal circulation.
Results
Bubble size over time is highly nonlinearly dependent on multiple factors, including diffusivity, solubility, gas partial pressures, magnitude of concentration gradients, vessel diameter, and temperature. Xenon- and oxygen-containing bubbles continue to grow during xenon delivery. Bubble volume doubles from 50 to 100 nl in approximately 3-68 min, depending on initial gas composition and bubble shape. Bubble growth and reabsorption are relatively insensitive to temperature in the physiologic and surgical range.
Conclusions
Xenon anesthesia results in gas exchange conditions that favor bubble growth, which may worsen neurologic injury from gas embolism. The concentration gradients can be manipulated by discontinuation of xenon delivery to promote reabsorption of xenon-containing bubbles. Estimated growth and reabsorption rates at normothermia can be applied to temperature extremes of cardiopulmonary bypass.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Anesthesiology and Pain Medicine
Cited by
25 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献