Affiliation:
1. *‡Staff Anesthesiologist, §Resident, ∥Professor and Chairman, Department of Anesthesiology, †Staff Radiologist, Department of Radiology, #Professor, Departments of Anesthesiology and Emergency Medicine and Surgery.
Abstract
Background
Traumatic aortic injury is a frequent cause of death after blunt trauma, but few patients survive to reach a trauma center. The role of transesophageal echocardiography (TEE) in the diagnosis of traumatic aortic injury remains debated.
Methods
Over a 9-yr period, 209 blunt trauma patients (mean age, 34 +/- 13 yr) were suspected of having traumatic aortic injury because of enlarged mediastinum and/or sudden deceleration, and underwent TEE and angiography (aortography and/or contrast-enhanced computed tomography.
Results
Traumatic aortic injury was diagnosed in 42 patients (20%). Angiography (aortography and/or contrast-enhanced computed tomography) was less accurate (sensitivity, 83%; specificity, 100%) than TEE (sensitivity, 98%; specificity, 100%) for the diagnosis of aortic injury because it failed to diagnose most minor injuries (intramural hematoma or limited intimal flap, n = 7). However, when considering only patients with major aortic injury (n = 33; i.e., those who might need surgery), angiography (sensitivity, 97%; specificity, 100%) and TEE (sensitivity, 97%; specificity, 100%) were equivalent.
Conclusion
Transesophageal echocardiography is an accurate method for diagnosis of traumatic aortic injury. Nevertheless, the clinical implications of limited aortic injuries diagnosed by the technique have yet to be determined.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Anesthesiology and Pain Medicine
Cited by
90 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献