Affiliation:
1. Associate Professor.
2. Associate Professor, Department of Obstetrics and Gynaecology.
3. Adjunct Assistant Professor, Department of Anaesthesia and Intensive Care.
Abstract
Background
Although ephedrine is usually recommended as the first-line vasopressor in obstetrics, its superiority over other vasopressors has not been proven in humans.
Methods
In a double-blind study, the authors randomized women having elective cesarean section with spinal anesthesia to receive an intravenous infusion of ephedrine, starting at 5 mg/min (n = 25), or metaraminol, starting at 0.25 mg/min (n = 25), titrated to maintain systolic arterial pressure in the target range 90-100% of baseline. Umbilical cord gases, maternal hemodynamics, uterine artery puLsatility index, and Apgar scores were compared.
Results
Systolic arterial pressure was maintained more closely in the target range in the metaraminol group compared with the ephedrine group. In the metaraminol group, umbilical arterial pH was greater (median and interquartile range, 7.31 and 7.31-7.33 vs. 7.24 and 7.14-7.29; P < 0.0001), and umbilical venous pH was greater (7.36 and 7.35-7.38 vs. 7.33 and 7.26-7.34; P < 0.0001) compared with the ephedrine group. No patient in the metaraminol group had umbilical arterial pH less than 7.2, compared with nine patients (39%) in the ephedrine group (P = 0.0005). Apgar scores were similar between groups. Changes in uterine artery pulsatility index were similar between groups.
Conclusions
When used by infusion to maintain arterial pressure during spinal anesthesia for cesarean section, metaraminol was associated with less neonatal acidosis and more closely controlled titration of arterial pressure compared with ephedrine.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Anesthesiology and Pain Medicine
Cited by
113 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献