Abstract

Background Lumbar epidural blood patch (EBP) is a common treatment of post-dural puncture headache, but its effectiveness and mode of action remain a matter of debate. The aim of this study was to assess both the effectiveness and the predictive factors of failure of EBP on severe post-dural puncture headache. Methods This prospective observational study includes all patients treated in the authors' hospital with EBP for incapacitating post-dural puncture headache, from 1988 to 2000. The EBP effect was classified into complete relief (disappearance of all symptoms), incomplete relief of symptoms (clinically improved patients who recovered sufficiently to perform normal daily activity), and failure (persistence of severe symptoms). The following data were analyzed using a logistic regression to identify predictive factors of failure of EBP: (1) patient characteristics; (2) circumstances of dural puncture; (3) delay between dural puncture and EBP; and (4) the volume of blood injected for EBP. Results A total of 504 patients were analyzed. The frequency rates of complete relief, incomplete relief of symptoms, and failure after EBP were 75% (n = 377), 18% (n = 93), and 7% (n = 34), respectively. In a multivariate analysis, only the diameter of the needle used to perform dura mater puncture (odds ratio = 5.96; 95% confidence interval, 2.63-13.47; P < 0.001) and a delay in EBP less than 4 days (odds ratio = 2.63; 95% confidence interval, 1.06-6.51; P = 0.037) were independent significant risk factors for a failure of EBP. Conclusions Epidural blood patch is an effective treatment of severe post-dural puncture headache. Its effectiveness is decreased if dura mater puncture is caused by a large bore needle.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference31 articles.

Cited by 237 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3