Technique for Using Video Microscopy and Indicator Dilution for Repeated Measurements of Cardiac Output in Small Animals

Author:

Rivers Richard J.1,Beckman Judy B.2,Frame Mary D. S.3

Affiliation:

1. Associate Professor, Departments of Anesthesiology, Pharmacology and Physiology, and Biomedical Engineering.

2. Technical Associate, Department of Anesthesiology.

3. Assistant Professor, Departments of Anesthesiology and Biomedical Engineering.

Abstract

Background The authors developed an indicator dilution technique for small animals to repeatedly determine cardiac output and blood volume without cardiac instrumentation or blood sampling. Methods Observations were made in the hamster (N = 32, 70 mg/kg pentobarbital) cremaster using in vivo fluorescence videomicroscopy. Fluorescein isothiocyanate-conjugated bovine serum albumin (10 mg/ml) was injected as a bolus dose (right jugular) while video recording the light intensity in a 20-microm arteriole (intensified charge-coupled device [CCD] camera at fixed gain). The intensity signal was analyzed over time (background subtracted) and calibrated to the dye concentration. The ex vivo calibration was performed using a constant optical path length (20 microm) and a range of dye and hematocrit concentrations. In vivo tube hematocrit was determined using standard methods with fluorescently labeled erythrocytes. Thus, quenching of the fluorescence signal by hemoglobin was corrected for the calibration, and the plasma space in the arteriole was determined. The steady state dye concentration measured by the light intensity at 2 min was not different from the dye concentration found by direct spectrophotometric analysis of the plasma. Results Cardiac index was calculated as milliliters of blood per minute per kilogram body weight. The calculated cardiac index was 359 +/- 18 ml.min(-1).kg(-1), which is not different from the reported values for hamsters. Cardiac output was increased twofold when enough intravenous nitroprusside or nitroglycerine was injected to decrease mean arterial pressure from 90 to 70 mmHg. Cardiac output was elevated during dobutamine infusion (16 microg.kg(-1).min(-1)) and decreased during esmolol infusion (50, 75.kg(-1).min(-1)). Blood volume determined from the steady state dye concentrations was 6.2 +/- 0.5 ml/100 g body weight, within the normal range for hamsters. Conclusions Fluorescent dye dilution and video microscopy can be used to repeatedly determine cardiac output or blood volume in small animals.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference15 articles.

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3