Minimum Alveolar Concentration–Awake of Xenon Alone and in Combination with Isoflurane or Sevoflurane

Author:

Goto Takahisa1,Nakata Yoshinori2,Ishiguro Yoshiki3,Niimi Yoshinari1,Suwa Kunio4,Morita Shigeho5

Affiliation:

1. Associate Professor.

2. Associate Professor, Departments of Health Original Investigations and Anesthesia, Teikyo University School of Medicine, Tokyo.

3. Assistant Professor.

4. Professor.

5. Professor and Chairman, Department of Anesthesia, Teikyo University School of Medicine, Ichihara Hospital.

Abstract

Background The minimum alveolar concentration (MAC)-awake is a traditional index of hypnotic potency of an inhalational anesthetic. The MAC-awake of xenon, an inert gas with anesthetic properties (MAC = 71%), has not been determined. It is also unknown how xenon interacts with isoflurane or sevoflurane on the MAC-awake. Methods In the first part of the study, 90 female patients received xenon, nitrous oxide (N2O), isoflurane, or sevoflurane supplemented with epidural anesthesia (n = 36 for xenon and n = 18 per group for other anesthetics). In the second part, 72 additional patients received either xenon or N2O combined with the 0.5 times MAC-awake concentration of isoflurane or sevoflurane (0.2% and 0.3%, respectively, based on the results of the first part; n = 18 per group). During emergence, the concentration of an assigned anesthetic (xenon or N2O only in the second part) was decreased in 0. 1 MAC decrements every 15 min from 0.8 MAC or from 70% in the case of N2O until the patient followed the command to either open her eyes or to squeeze and release the investigator's hand. The concentration midway between the value permitting the first response to command and that just preventing it was defined as the MAC-awake. Results The MAC-awake were as follows: xenon, 32.6 +/- 6.1% (mean +/- SD) or 0.46 +/- 0.09 MAC; N2O, 63.3 +/- 7.1% (0.61 +/- 0.07 MAC); isoflurane, 0.40 +/- 0.07% (0.35 +/- 0.06 MAC); and sevoflurane, 0.59 +/- 0.10% (0.35 +/- 0.06 MAC). Addition of the 0.5 MAC-awake concentrations of isoflurane and sevoflurane reduced the MAC-awake of xenon to 0.50 +/- 0.15 and 0.51 +/- 0.16 times its MAC-awake as a sole agent, but that of N2O to the values significantly greater than 0.5 times its MAC-awake as a sole agent (0.68 +/- 0.12 and 0.66 +/- 0.14 times MAC-awake; P < 0.01, analysis of variance and Dunnett's test). Conclusions The MAC-awake of xenon is 33% or 0.46 times its MAC. In terms of the MAC-fraction, this is smaller than that for N2O but greater than those for isoflurane and sevoflurane. Unlike N2O, xenon interacts additively with isoflurane and sevoflurane on MAC-awake.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference33 articles.

Cited by 53 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3