Prediction of Movement during Propofol/Nitrous Oxide Anesthesia

Author:

Leslie Kate,Sessler Daniel I.,Smith Warren D.,Larson Merlin D.,Ozaki Makoto,Blanchard Don,Crankshaw David P.

Abstract

Background Movement in response to painful stimulation is the end point classically used to assess the potency of anesthetic agents. In this study, the ability of modeled propofol effect-site concentration to predict movement in volunteers during propofol/nitrous oxide anesthesia was tested, then it was compared with the predictive abilities of the Bispectral Index and 95% spectral edge frequency of the electroencephalogram, pupillary reflex amplitude, and systolic arterial blood pressure. In addition, the relationships between simple end points of loss and recovery of consciousness, and pupillary, hemodynamic, and propofol concentration indicators were studied. Methods Ten healthy volunteers were anesthetized with an infusion of propofol, which was increased in three equal steps to 21 mg.kg lean body mass-1.h-1. After loss of the ability to hold a syringe and of the eyelash reflex, 60% nitrous oxide was introduced and the trachea was intubated without the use of muscle relaxants. The propofol infusion rate then was decreased to 15.4 mg.kg lean body mass-1.h-1. Ten minutes later, tetanic electrical stimulation was administered to the thigh via needle electrodes: if movement was observed within 1 min, the propofol infusion rate was increased by 1.75 mg.kg lean body mass-1.h-1 5 min after the stimulus; if not, it was similarly decreased. This 15-min sequence was repeated until volunteers "crossed over" from movement to no movement (or vice versa) four times. The propofol infusion rate then was increased to 21 mg.kg lean body mass-1.h-1, nitrous oxide was discontinued, the trachea was extubated, and the infusion rate was decreased in five equal steps over 50 min. The times at which the eyelash reflex returned and the birth date was recalled were recorded. The electroencephalogram was monitored continuously (FP1, FP2, ref: nasion, ground: mastoid). Measurements of the pupillary response, arterial blood pressure, and heart rate were recorded during induction and awakening, just before and for 5 min after each stimulation. Arterial blood samples were obtained for propofol assay, and propofol effect-site concentrations were calculated at each time. The predictive value of indicators was compared using a new static, the prediction probability (PK). Results Loss and return of the eyelash reflex occurred at greater propofol effect-site concentrations than either dropping the syringe or recall of the birthday. The propofol effect-site concentration (in the presence of 60% nitrous oxide) predicted to prevent movement after a supramaximal stimulus in 50% of volunteers was 1.80 micrograms/ml (95% confidence limits: 1.40-2.34 micrograms/ml). The Bispectral Index (PK = 0.86), 95% spectral edge frequency (PK = 0.81), pupillary reflex amplitude (PK = 0.74), and systolic arterial blood pressure (PK = 0.78) did not differ significantly from modeled propofol effect-site concentration (PK = 0.76) in their ability to predict movement. Conclusions Indicators of pharmacodynamic effect, such as the electroencephalogram, pupillary light reflex, and systolic arterial blood pressure, predict movement as well as effect-site concentration during propofol/nitrous oxide anesthesia. Loss and return of the eyelash reflex correspond to a deeper level of anesthesia than syringe-dropping or recall of the birth date.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference40 articles.

Cited by 135 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3