Using Front-end Kinetics to Optimize Target-controlled Drug Infusions

Author:

Avram Michael J.1,Krejcie Tom C.2

Affiliation:

1. Associate Professor of Anesthesiology.

2. Professor of Anesthesiology.

Abstract

Background The mode of drug administration, blood sampling schedule, and sampling site affect the pharmacokinetic model derived. The present study tested the hypothesis that three-compartment pharmacokinetic model parameters derived from arterial drug concentrations obtained after rapid intravenous administration can be used to design a target-controlled drug infusion (TCI) that deviates minimally from the target. Methods Arterial thiopental concentration data obtained from the moment of injection in a previous study of five dogs were used. Three three-compartment models were constructed, one based on early concentrations classically obtained at 1, 2, and 3 min; another using all concentrations obtained beginning with the thiopental recirculation peak; and the last with the initial distribution volume (VC) fixed to the sum of VC and the nondistributive volume of the recirculatory model from the earlier study. Using these models, TCIs were designed that would maintain 20 mug/ml thiopental concentrations in VC for 60 min if simulated with the models used in their design. Drug concentrations resulting from these TCIs were then simulated using recirculatory model kinetics, and prediction errors were evaluated. Results Models with VCs estimated from intermittent or frequent early blood concentrations overestimated not only VC but also the volume and clearance of the rapidly equilibrating tissues, and their TCIs significantly overshot the target. With VC fixed to recirculatory model parameters, drug distribution was described in a manner consistent with that of the recirculatory model, and the TCI deviated minimally from the target. A similar three-compartment model was derived from data obtained from a simulation of a 2-min infusion using recirculatory kinetic parameters. Conclusions Because three-compartment models based on drug concentration histories obtained after rapid intravenous administration do not characterize VC accurately, TCIs based on them produce concentrations exceeding the target. A model capable of producing TCIs deviating minimally from the target can be derived from data obtained during and after a brief drug infusion.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference33 articles.

Cited by 72 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3