Influence of Nitrous Oxide on Minimum Alveolar Concentration of Sevoflurane for Laryngeal Mask Insertion in Children

Author:

Kihara Shinichi1,Yaguchi Yuichi1,Inomata Shinichi2,Watanabe Seiji3,Brimacombe Joseph R.4,Taguchi Noriko1,Komatsuzaki Tetsuya5

Affiliation:

1. Staff Anesthetist.

2. Assistant Professor, Department of Anesthesia, University of Tsukuba.

3. Chief Anesthetist.

4. Professor, Department of Anesthesia and Intensive Care, University of Queensland and James Cook University, Cairns Base Hospital.

5. Resident, Department of Anesthesia, Mito Saiseikai General Hospital.

Abstract

Background Inhalational induction with sevoflurane and nitrous oxide is frequently used for Laryngeal Mask Airway (LMA; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) insertion in children. The authors determined the influence of nitrous oxide on the minimum alveolar concentration (MAC) of sevoflurane for LMA insertion. Methods One hundred twenty unpremedicated children (age, 1-9 yr; American Society of Anesthesiologists physical status I) were randomly assigned to receive 1 of 15 end-tidal concentrations of nitrous oxide and sevoflurane for inhalational induction via a facemask: 0% nitrous oxide with 1.2, 1.4, 1.6, 1.8, or 2.0% sevoflurane; 33% nitrous oxide with 0.8, 1.0, 1.2, 1.4, or 1.6% sevoflurane; or 67% nitrous oxide with 0.4, 0.6, 0.8, 1.0, or 1.2% sevoflurane. The LMA was inserted after steady state end-tidal anesthetic concentrations had been maintained for 15 min. The response to insertion was recorded by three independent blinded observers. The interaction between nitrous oxide and sevoflurane was determined using logistic regression analysis. Results The MAC of sevoflurane for LMA insertion (95% confidence limit) was 1.57% (1.42-1.72%), and the concentration of sevoflurane required to prevent movement in 95% of children was 1.99% (1.81-2.57%). The addition of 33% and 67% nitrous oxide linearly decreased the MAC of sevoflurane for LMA insertion by 22% and 49%, respectively (P < 0.001). The interaction coefficient between nitrous oxide and sevoflurane did not differ from zero (P = 0.7843), indicating that the relation was additive. Conclusions Nitrous oxide and sevoflurane suppress the responses to LMA insertion in a linear and additive fashion in children.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference13 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3