Abstract

Background Anesthetic potency is assessed by determination of the anesthetic concentration that prevents gross, purposeful movement in response to noxious stimulation. It is unclear whether anesthetics cause a progressive decrease in the number and force of limb movements evoked by noxious stimulation, or a step decrease (consistent with an all-or-none effect at the site of action). The authors hypothesized that isoflurane and halothane would progressively depress the movement response. Methods Isoflurane minimum alveolar concentration (MAC) was determined in rats (N = 14) using a clamp applied to a hind paw. Lateral head movements and flexions of the forelimbs and hindlimbs were measured with force transducers. Isoflurane was adjusted to 0.6, 0.9, 1.1, and 1.4 MAC, the noxious stimulus applied, and the force and number of limb and head movements determined. Force and movement determinations were made in seven additional halothane-anesthetized rats. Results Isoflurane MAC was 1.3 +/- 0.1%. In general, if movement occurred after application of the noxious clamp, the head and all limbs were involved. At 0.6 MAC, the median number of extremity and head movements was 3.5 (10th-90th percentile, 2.0-11.4) with force generated per movement (force/movement) = 6.4 (2.0-13.2) N-s. Movement number decreased to 2.1 (0.25-4.2) at 0.9 MAC (P < 0.05), but force/movement was unchanged at 4.5 (0.4-15.1) N-s (Newton-second). At 1.1 MAC, movement number and force/movement decreased to 0.2 (0.0-1.5) and 0.1 (0.0-3.2) N-s, respectively (P < 0.005). No significant movement occurred at 1.4 MAC. The halothane-anesthetized rats had similar findings, although at 0.6 MAC they generated more movements (10.5 [5.2-19.8]) than the rats receiving isoflurane (P < 0.05). Conclusions The results indicate that increasing anesthetic concentration from 0.6 to 0.9 MAC had little effect on the motor system controlling the force of limb movements, and the neural system generating repeated limb movements was depressed, consistent with a differential anesthetic effect at separate sites.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference26 articles.

Cited by 37 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3