Computer assisted interpretation of Tc-99m mercaptoacetyltriglycine diuretic scintigraphy enhances resident performance

Author:

Taylor Andrew T.1,Fazlur Rahman A.K.M.2,Folks Russell D.1,Moncayo Valeria1,Savir-Baruch Bital1,Plaxton Nicholas3,Polsani Aruna4,Halkar Raghuveer K.1,Dubovsky Eva V.5,Garcia Ernest V.1,Manatunga Amita6

Affiliation:

1. Department of Radiology and Imaging Sciences, School of Medicine, Emory University, Atlanta, Georgia

2. Department of Biostatistics, University of Alabama, Birmingham, Alabama

3. Bay Pines VA Health Care System, Bay Pines Florida

4. Zenith Radiology, LLC, Richmond, Kentucky

5. Department of Radiology, University of Alabama, Birmingham, Alabama

6. Department of Biostatistics and Bioinformatics, School of Public Health, Emory University, Atlanta Georgia, USA

Abstract

Objective iRENEX is a software module that incorporates scintigraphic and clinical data to interpret 99mTc- mercaptoacetyltriglycine (MAG3) diuretic studies and provide reasons for their conclusions. Our objectives were to compare iRENEX interpretations with those of expert physicians, use iRENEX to evaluate resident performance and determine if iRENEX could improve the diagnostic accuracy of experienced residents. Methods Baseline and furosemide 99mTc-MAG3 acquisitions of 50 patients with suspected obstruction (mean age ± SD, 58.7 ± 15.8 years, 60% female) were randomly selected from an archived database and independently interpreted by iRENEX, three expert readers and four nuclear medicine residents with one full year of residency. All raters had access to scintigraphic data and a text file containing clinical information and scored each kidney on a scale from +1.0 to −1.0. Scores ≥0.20 represented obstruction with higher scores indicating greater confidence. Scores +0.19 to −0.19 were indeterminate; scores ≤−0.20 indicated no obstruction. Several months later, residents reinterpreted the studies with access to iRENEX. Receiver operating characteristic (ROC) analysis and concordance correlation coefficient (CCC) quantified agreement. Results The CCC among experts was higher than that among residents, 0.84, versus 0.39, respectively, P < 0.001. When residents reinterpreted the studies with iRENEX, their CCC improved from 0.39 to 0.73, P < 0.001. ROC analysis showed significant improvement in the ability of residents to distinguish between obstructed and non-obstructed kidneys using iRENEX (P = 0.036). Conclusion iRENEX interpretations were comparable to those of experts. iRENEX reduced interobserver variability among experienced residents and led to better agreement between resident and expert interpretations.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Reference22 articles.

1. Survey on the use of nuclear renal imaging in the United States.;Archer;J Nucl Med Technol,2016

2. RENEX: an expert system for the interpretation of Tc-99m MAG3 scans to detect renal obstruction.;Garcia;J Nucl Med,2006

3. Diagnostic performance of an expert system for interpretation of Tc-99m MAG3 scans in suspected obstruction.;Taylor;J Nucl Med,2008

4. iRENEX: a clinically-informed decision support system for the interpretation of Tc-99m MAG3 scans to detect renal obstruction.;Garcia;Eur J Nucl Med Mol Imaging,2012

5. A software engine to justify the conclusions of an expert system for detecting renal obstruction on Tc-99m MAG3 scans.;Garcia;J Nucl Med,2007