Abstract

Aim [123]I-Ioflupane (DaTSCAN) binds to the presynaptic dopamine transporter (DAT) and with a lower affinity to the serotonin transporter (SERT). We aimed to develop a novel method to quantify absolute uptake in the striatal (predominantly DAT binding) and extra-striatal regions (mainly SERT binding) using single-photon computed tomography-computed tomography (SPECT-CT) DaTSCAN and to improve DaTSCAN image quality. Method Twenty-six patients with Parkinsonism underwent DaTSCAN SPECT-CT prospectively. The scans were visually analyzed independently by two experienced reporters. Specific binding ratios (SBRs) from Chang attenuation corrected SPECT were obtained using GE DaTQuant. Normalized concentrations and specific uptakes (NSU) from measured attenuation and modelled scatter-corrected SPECT-CT were obtained using HERMES Hybrid Recon and Affinity and modified EARL volumes of interest. Results Striatal NSU and SBR positively correlate (R = 0.65–0.88, P = 0.00). SBR, normalized concentrations, and NSU box plots differentiated between scans without evidence of dopaminergic deficit and abnormal scans. Interestingly, body weight inversely correlated with normalized concentrations values in extra-striatal regions [frontal (R = 0.81, P = 0.00); thalamus (R = 0.58, P = 0.00); occipital (R = 0.69, P = 0.00)] and both caudate nuclei [R = 0.42, P = 0.03 (Right), R = 0.52, P = 0.01 (Left)]. Both reporters noted improved visual quality of SPECT-CT versus SPECT images for all scans. Conclusion DaTSCAN SPECT-CT resulted in more accurate quantification, improved image quality, and enabled absolute quantification of extra-striatal regions. More extensive studies are required to establish the full value of absolute quantification for diagnosis and monitoring the progression of neurodegenerative disease, to assess an interplay between DAT and SERT, and to verify whether serotonin and DATs are potentially dysfunctional in obesity.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3