Affiliation:
1. IRCCS Multimedica, Milan
2. Department of Orthopaedic Surgery, “Federico II” University, Naples, Italy
Abstract
The suture button (SB) suspension technique has become popular in the treatment of thumb basal joint arthritis, as it works as an internal mean for metacarpal stabilization, demonstrating good results with improvement in function and strength. The aim of our study is to describe a new transosseous suture suspensionplasty technique using a simple Ethibond #2 suture as a substitute for the suture button and to report the postoperative clinical outcomes. In this study, we included a total of 14 patients with 2 years follow-up. We evaluated patients with the use of the Disabilities of the Arm, Shoulder and Hand questionnaire, the Visual Analog Scale, the Kapandji test, and the key pinch strength. Patients treated with transosseous suture suspensionplasty demonstrated clinical improvement at an average follow-up of 24 months. No complications were noted immediately after the procedure or during the 2-year follow-up period.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献