The “Standing Peanut” Scaphoid View: A Semi-supinated Radiographic View for Intraoperative Evaluation of Screw Placement in Scaphoid Waist Fractures

Author:

Shiver A. Luke,Wallace Doyle R.,Dolan Joshua D.,Jones Keri L.,Fulcher S. Mark

Abstract

Scaphoid waist fractures are the most common fracture of the scaphoid. Operative management is indicated with unstable fractures and often for nondisplaced waist fractures to decrease time to union and return to work/sport. Screw placement within the central axis of the scaphoid is paramount and correlates with outcomes. Assessment of intrascaphoid screw placement is classically done via intraoperative fluoroscopy. An additional fluoroscopic view is presented to assist in confirming implant positioning. Along with the standard anterioposterior, lateral, pronated oblique, and “scaphoid” view we obtain a “standing peanut” view for assessment of central screw placement. This view also allows for further evaluation of center/center positioning and better assessment of fixation crossing the fracture into the proximal pole. The “standing peanut” view is best obtained in a sequential manner beginning with the forearm in neutral rotation. First, the forearm is then supinated 30 degrees; next, the wrist is placed at 45 degrees of ulnar deviation. Then finally, 10 degrees of wrist extension. We utilize this additional intraoperative view in conjunction with the standard fluoroscopic views for assessing and ensuring center-center implant positioning, particularly within the proximal pole. When ensuring center-center positioning, we prefer this view as an adjunct view to the standard fluoroscopic views intraoperatively. It provides a beneficial view of the proximal pole delineating the number of screw threads that have obtained proximal pole purchase. We have found it particularly useful in the setting of scaphoid waist fracture nonunion with the classic ‘humpback’ deformity after correction with volar interposition grafting. Standard radiographic views may be misinterpreted regarding implant positioning if there remains any residual flexion. The view requires little in the way of training to obtain once appreciated and exposes the patient to minimal additional radiation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3