Pronator Quadratus Muscle Flap for Prevention of Flexor Tendon Rupture after Distal Radius Volar Plating

Author:

Husain Tarik M.1,Jabbour Jacob I.2,Sudduth Jack D.3,Lessard Anne-Sophie4,Patete Carissa L.5,Panthaki Zubin J.4,Salloum Gabe E.6

Affiliation:

1. MOSA Plastic Surgery, Miami Beach, Fla.

2. The Hand Center at HOCC, Hartford Healthcare Medical Group, New Britain, Conn.

3. Division of Plastic Surgery, University of Utah Hospital, Salt Lake City, Utah

4. Division of Plastic, Aesthetic, and Reconstructive Surgery, University of Miami Leonard M. Miller School of Medicine, Miami, Fla.

5. University of Miami Leonard M. Miller School of Medicine, Miami, Fla.

6. Miami Center for Plastic Surgery, Miami Beach, Fla.

Abstract

Background: Flexor tendon rupture is a serious but rare complication that can occur after volar plating of distal radius fractures. This study aims to introduce a novel surgical technique that uses a pronator quadratus (PQ) muscle flap transposition to protect the flexor tendons from rupture or irritation and evaluate its outcomes. Methods: A retrospective review was conducted on 204 patients with unstable distal radius fractures who underwent a standard volar flexor carpi radialis approach with extended release of the PQ muscle during exposure. A PQ muscle flap was harvested and transposed over the distal edge of the plate after open reduction and internal fixation of the distal radius. Postoperatively, patients were evaluated for flexor tendon irritation and rupture. Patients who had this injury before the use of the PQ flap were compared with the patients who received the PQ flap. Results: Of the 204 patients, 119 received the PQ flap, and 85 did not. The mean follow-up time was 30.4 months. Among the patients who did not receive the PQ flap, five (5.9%) required plate removal or conservative treatment for tendon irritation or rupture. In contrast, only one patient (0.8%) who received the PQ flap required plate removal for flexor tendon irritation. Conclusions: The PQ muscle flap is a quick and effective surgical technique that reduces the risk of flexor tendon rupture or irritation during distal radius fracture fixation. The PQ muscle flap acts as a buffer between the plate and tendon and is more effective than not transposing the muscle.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Surgery,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3