Ultrasonography as a Tool to Improve Preoperative Marking in Body Contour Surgery

Author:

Manzaneda Cipriani Raúl Martín1,Viaro Maurício1,Adrianzen Gerardo2,Flores Emmanuel3,Duran Vega Héctor4,Babaitis Ricardo5,Dal Ponte Zatt João Vitor1,Salonia Goldmann Ignacio6,Kornalewski de Oliveira Rafael6,de Souza Bisognin Laura7

Affiliation:

1. Private Practice, Lima, Peru

2. Faculty of Human Medicine Department, Cayetano Heredia University, Lima, Peru

3. Faculty of Human Medicine Department, Universidad Autónoma de México, Mexico City, Mexico

4. Private Practice, Merida Yucatán, Mexico

5. Private Practice, Buenos Aires, Argentina

6. Faculty of Human Medicine Department, Lutheran University, Rio Grande do Sul, Brazil, Brazil

7. Faculty of Human Medicine Department, Franciscan University, Santa Maria, Rio Grande do Sul, Brazil.

Abstract

Background: Body contouring surgery and surgical drawings are usually performed based on the surgeon’s experience without considering the nature of the unique anatomical structures of each patient. Thus, we propose a more reliable surgical design approach that considers the anatomical structures of each patient. Ultrasonography is increasingly used in plastic surgery and helps plastic surgeons to highlight anatomical features representing results in their interventions by providing a better understanding of the patients’ unique structures. Methods: This study presents a series of cases involving 100 recruited patients (36 men and 64 women) between 18 and 60 years of age. Five surgeons examined the patients and created a presurgical design based on palpation, which was validated later by a physician skilled in evaluating the anterior wall of the abdomen using ultrasonography. The concordance between the findings of the palpation and ultrasonography was assessed for each patient. Results: The concordance rate for each structure in both evaluations was midline (49%) (P > 0.92), diastasis recti (15%), semilunar line (23%), upper edge of rectus abdominis muscles (12%), lower edge of pectoral muscles (16%), border of oblique muscle (13%), number of tendinous intersections (12%), shape of tendinous intersections (11%), serratus anterior muscle (15%), subcostal triangle (15%), and oblique triangle (26%) (P < 0.0001). Conclusion: All the structures evaluated by palpation in comparison with ultrasound show discordance, except the midline where agreement is evident, with a very good level of statistical significance.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Surgery,General Medicine

Reference19 articles.

1. VASER-assisted high-definition liposculpture.;Hoyos;Aesthet Surg J,2007

2. Lipoaspiração laser-assistida de alta definição.;Motta;Rev Bras Cir Plást,2018

3. Ultra HD Liposuction: enhancing abdominal etching using ultrasound-guided rectus abdominis fat transfer (UGRAFT).;Viaro;Plast Reconstr Surg Glob Open,2020

4. Basic physics of ultrasound imaging.;Aldrich;Crit Care Med,2007

5. Plastic surgeon–led ultrasound.;Oni;Plast Reconstr Surg,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3