Fluorescence In Situ Hybridization as Diagnostic Tool for Implant-associated Infections: A Pilot Study on Added Value

Author:

Scheuermann-Poley Catharina1,Wiessner Alexandra2,Kikhney Judith2,Gatzer Renate3,Müller Martin3,Stichling Marcus1,Moter Annette2,Willy Christian1

Affiliation:

1. Trauma & Orthopedic Surgery, Septic & Reconstructive Surgery, Research and Treatment Centre Septic Defect Wounds, Federal Armed Forces of Germany, Bundeswehr (Military) Academic Hospital, Berlin, Germany

2. Biofilmcenter, Institute for Microbiology, Infectious Diseases, and Immunology, Charité – University Medicine Berlin and MoKi Analytics GmbH, Berlin, Germany

3. Department of Microbiology, Federal Armed Forces of Germany, Bundeswehr (Military) Academic Hospital, Berlin, Germany.

Abstract

Background: Implant-associated infections are a devastating complication in surgery. Especially in infections with biofilm-forming microorganisms, the identification of the causing microorganism remains a challenge. However, the classification as biofilm is not possible with conventional polymerase chain reaction or culture-based diagnostics. The aim of this study was to evaluate the additional value of fluorescence in situ hybridization (FISH) and nucleic acid amplification technique (FISHseq) to discuss a diagnostic benefit of the culture-independent methods and to map spatial organization of pathogens and microbial biofilms in wounds. Methods: In total, 118 tissue samples from 60 patients with clinically suspected implant-associated infections (n = 32 joint replacements, n = 24 open reduction and internal fixation, n = 4 projectiles) were analyzed using classic microbiological culture and culture-independent FISH in combination with polymerase chain reaction and sequencing (FISHseq). Results: In 56 of 60 wounds, FISHseq achieved an added value. FISHseq confirmed the result of cultural microbiological examinations in 41 of the 60 wounds. In 12 wounds, one or more additional pathogens were detected by FISHseq. FISHseq could show that the bacteria initially detected by culture corresponded to a contamination in three wounds and could exclude that the identified commensal pathogens were a contamination in four other wounds. In five wounds, a nonplanktonic bacterial life form was detected. Conclusions: The study revealed that FISHseq gives additional diagnostic information, including therapy-relevant findings that were missed by culture. In addition, nonplanktonic bacterial life forms could also be detected with FISHseq, albeit less frequently than previously indicated.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Surgery,General Medicine

Reference56 articles.

1. New methods for the detection of orthopedic and other biofilm infections.;Costerton;FEMS Immunol Med Microbiol,2011

2. Predebridement wound culture in open fractures does not predict postoperative wound infection: a pilot study.;Lingaraj;J Nat Sci Biol Med,2015

3. Predisposing factors for early infection in patients with open fractures and proposal for a risk score.;Matos;J Orthop Traumatol,2015

4. Hip and knee replacement in Germany and the USA: analysis of individual inpatient data from German and US hospitals for the years 2005 to 2011.;Wengler;Dtsch Arztebl Int,2014

5. Infection after fracture fixation: current surgical and microbiological concepts.;Metsemakers;Injury,2018