A Comparison of Dye Versus Fluorescence Methods for Sentinel Lymph Node Mapping in Endometrial Cancer

Author:

Yamagami Wataru,Susumu Nobuyuki,Kataoka Fumio,Makabe Takeshi,Sakai Kensuke,Ninomiya Tomomi,Wada Michiko,Nomura Hiroyuki,Hirasawa Akira,Banno Kouji,Nakahara Tadaki,Kameyama Kaori,Aoki Daisuke

Abstract

ObjectiveSentinel nodes (SNs) have been observed in several reports from Japan and overseas in cases with endometrial cancer; however, no consensus has been reached regarding the types of tracers or the method of their injection. A combination of the radioisotope (RI) and dye method is considered to be desirable. We assessed SN mapping using either dye or near-infrared fluorescence imaging to clarify a suitable method in cases of endometrial cancer.MethodsPatients were enrolled from 92 patients diagnosed with endometrial cancer and having no extrauterine metastasis by the preoperative imaging between 2009 and 2014 at our institution. To identify the SNs, we performed 3 methods using either dye or fluorescence solutions in conjunction with a RI method. In the dye method, we injected indocyanine green in the uterine subserosa, visually identifying SNs as stained green. In the fluorescence method, a dilute indocyanine green solution (0.5 mg, fluorescence A or 0.25 mg, fluorescence B, each per 10 mL of solvent) was injected and the SN identified by the HyperEye Medical System.ResultsThe SN detection rates were 100%, 100%, and 96% using dye and fluorescence A or B solution, respectively. Pelvic SNs were detected by the 3 methods in 98%, 100%, and 96% of cases and para-aortic SNs in 65%, 88%, and 74%, respectively. Fluorescence A solution was somewhat better than dye in detecting para-aortic SNs, although not significantly so (P = 0.07). The sensitivity and negative predictive values for detecting SNs with metastases with the dye method were 92% and 98% compared with 100% and 100%, respectively, for both fluorescence solutions.ConclusionsAlthough both dye and fluorescence methods performed well, no method perfectly identified para-aortic SNs. The concomitant use of the RI method is required to detect para-aortic SNs.

Publisher

BMJ

Subject

Obstetrics and Gynecology,Oncology

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3