Capsule Dynamics, Implantation, and Explantation of the Smaller Incision, New-Generation Implantable Miniature Telescope: a Miyake–Apple Study

Author:

Hammer Maximilian12,Schickhardt Sonja1,Zhang Lu1,Munro Donald1,Yildirim Timur M.12,Auffarth Gerd U.12

Affiliation:

1. The David J Apple International Laboratory for Ocular Pathology, Heidelberg, Germany; and

2. Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany.

Abstract

Purpose: The smaller incision, new-generation implantable miniature telescope is a novel implant to optimize vision in retinal patients with central vision loss. Using Miyake–Apple techniques we visualized the device implantation, repositioning, and explantation, while noting capsular bag dynamics. Methods: Using the Miyake–Apple technique, we assessed capsular bag deformation after successful implantation of the device in human autopsy eyes. We assessed rescue strategies for converting a sulcus implantation to a capsular implantation and explantation strategies. We noted the occurrence of posterior capsule striae, zonular stress, and the haptics' arc of contact with the capsular bag after implantation. Results: Acceptable zonular stress was observed during the successful implantation of the SING IMT. When it was implanted in the sulcus, one could reposition the haptics into the bag with two spatulas using counter-pressure in an effective strategy despite inducing tolerable, medium zonular stress. A similar technique, in reverse, allows safe explantation without damaging the rhexis or the bag, while inducing similar medium, tolerable zonular stress. In all eyes we examined, the implant considerably stretches the bag, inducing a capsular bag deformation and posterior capsule striae. Conclusion: The SING IMT can be safely implanted without significant zonular stress. In sulcus implantation and explantation, repositioning of the haptic is achievable without perturbing zonular stress using the presented approaches. It stretches average-sized capsular bags to support its weight. This is achieved by an increased arc of contact of the haptics with the capsular equator.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Scleral fixation of the Smaller-Incision New Generation Implantable Miniature Telescope (SING IMT™);Graefe's Archive for Clinical and Experimental Ophthalmology;2024-03-25

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3