New Versus Old—How Reliable Is the New OTA/AO Classification for Trochanteric Hip Fractures?

Author:

Davidson Amit12ORCID,Revach Yuval3,Rodham Paul2,Mosheiff Rami1,Kandel Leonid1,Weil Yoram A.1

Affiliation:

1. Orthopaedic Department, Hadassah Hebrew University Hospital, Jerusalem, Israel;

2. Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, United Kingdom; and

3. Hebrew University Medical School, Jerusalem, Israel.

Abstract

Objective: To evaluate the intraobserver and interobserver reliability of the 2018 OTA/AO trochanteric hip fracture (THF) classification compared with the 1983 OTA/AO Muller classification system. To further delineate the reliability of classifying stable and unstable THF using the 2 classification systems. Design: Radiographic observational study. Setting: Multicenter, one Level 1 and one Level 2 trauma centers. Participants/Patients: Seventy-three radiographic series of patients treated operatively for THF were evaluated by 6 orthopaedic surgeons. Intervention: The OTA/AO THF classification system was applied by each surgeon to 73 cases in 2 independent assessments performed 4 weeks apart: once by the old classification followed by the new 2018 OTA/AO classification. Each radiographic series included lateral hip and anteroposterior initial radiographs. Eight random cases were duplicated in each of the surveys to evaluate the intraobserver reliability. Main Outcome Measurements: Intraobserver and interobserver of the group, subgroup and fracture stability classification determined by the interclass coefficient (ICC) and Cohen kappa values. Results: The interobserver reliability for the group classification (31A1/A2/A3) was moderate using the new classification, whereas substantial agreement was shown using the old classification (0.49 and 0.69, respectively). The reliability of the fracture stability classification was higher using the old classification (0.70 vs. 0.52). Subgroup classifications interobserver agreement was fair for both classification systems, although lower reliability was shown in the old classification (0.34 vs. 0.31). Conclusions: The new OTA/AO classification has a lower interobserver reliability for THF classification when compared with the old one.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3