Mapping of Pelvic Ring Injuries From High-Energy Trauma Using Unfolded CT Image Technology

Author:

Mills Andrew T.1ORCID,LaRoque Michael C.12ORCID,Thomas Claire N.12ORCID,George Albert V.1ORCID,Albright Patrick A.12ORCID,Cole Peter A.123

Affiliation:

1. Department of Orthopaedic Surgery, Regions Hospital, St. Paul, MN;

2. Department of Orthopaedic Surgery, University of Minnesota Medical School, Minneapolis, MN; and

3. HealthPartners Orthopaedics & Sports Medicine, Bloomington, MN.

Abstract

Objectives: High-energy pelvic ring injuries are associated with significant morbidity and mortality, elevating the importance of injury pattern identification. The purpose of this study was to use a novel 3D computed tomography (CT) unfolding process to both evaluate high-energy pelvic ring injures and to produce injury frequency maps based on injury patterns. Methods: Patients 18–65 years of age presenting to a level 1 trauma center with pelvic ring injuries between 2016 and 2020 were identified. Of the 482 patients reviewed, 355 were excluded primarily due to having a low energy mechanism, inadequate radiographs, or an isolated fracture. Unfolded pelvic CT images were created using syngo.via CT Bone Reading software. Pelvic ring injury frequency maps were created using the unfolded pelvic CT images and a previously described mapping technique. Results: One hundred twenty-seven patients analyzed had a mean age of 32.7 years. The most common mechanisms of injury (MOI) were motor vehicle collision (30.7%) and fall from height (23.6%). The breakdown of pelvic ring injuries included LC1 = 44.1%, LC2 = 7.1%, LC3 = 14.2%, APC1 = 2.4%, APC2 = 15.0%, APC3 = 5.5%, and VS = 11.8%, with OTA/AO-61B = 74.0% and OTA/AO-61C = 26.0%. Pelvic ring mapping revealed that articular and bony injuries varied markedly between the different types of pelvic ring disruptions, both in type and location. Conclusions: Pelvic ring injury frequency maps created from unfolded CT images reflect consistent injury patterns providing distinctive information based on force vector mechanisms. Unfolded CT images allow for a novel way to visualize pelvic ring injuries which yield greater comprehension of failure patterns with implications for treatment.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3