Ultrasound Assessment of Ankle Syndesmotic Injuries in a Pediatric Population

Author:

Heitz Pierre-Henri12,Miron Marie-Claude34,Beauséjour Marie15,Hupin Mathilde12,DiLiddo Lydia67,Jourdain Nathalie8,Nault Marie-Lyne129

Affiliation:

1. Department of Surgery, CHU Sainte-Justine, Montréal, QC, Canada;

2. Department of Surgery, Université de Montréal, Edouard-Montpetit, Montréal, QC, Canada;

3. Department of Radiology, CHU Sainte-Justine, Montréal, QC, Canada;

4. Department of Radiology, Université de Montréal, Edouard-Montpetit, Montréal, QC, Canada;

5. Department of Surgery, Université de Sherbrooke, Université de Sherbrooke—Campus Longueuil, Longueuil, QC, Canada;

6. Department of Pediatrics, CHU Sainte-Justine, Montréal, QC, Canada;

7. Department of Pediatrics, Université de Montréal, Edouard-Montpetit, Montréal, QC, Canada;

8. Research Center, CHU Sainte-Justine, Montréal, QC, Canada; and

9. Department of Surgery, Hôpital du Sacré-Coeur de Montréal, Montreal, QC, Canada.

Abstract

Objective: To determine sensitivity and specificity for anterior-inferior tibiofibular ligament (AiTFL) integrity and tibiofibular clear-space (TFCS) cut-off points for dynamic evaluation using ultrasound (US) in a pediatric population. Design: Prospective cohort study. Setting: Tertiary care university-affiliated pediatric hospital patients between the ages of 12 and 18 sustaining acute ankle trauma with syndesmotic injury. Interventions: Participants were assigned to the syndesmotic injury protocol that included a standardized MRI and US. Main Outcome Measures: Anterior-inferior tibiofibular ligament integrity for static assessment and TFCS measurements for dynamic assessment on US. For dynamic assessment, the distance between the distal tibia and fibula was first measured in neutral position and then in external rotation for each ankle. The US results on AiTFL integrity were compared with MRI, considered as our gold standard. Optimal cut-off points of TFCS values were determined with receiver operating characteristics curve analysis. Results: Twenty-six participants were included. Mean age was 14.8 years (SD = 1.3 years). Sensitivity and specificity for AiTFL integrity were 79% and 100%, respectively (4 false negatives on partial tears). For dynamic assessment, the cut-off points for the differences in tibiofibular distance between the 2 ankles in 1) neutral position (TFCS N I-U) and 2) external rotation (TFCS ER I-U) were 0.2 mm (sensitivity = 83% and specificity = 80%) and 0.1 mm (sensitivity = 83% and specificity = 80%), respectively. Conclusions: Static US could be used in a triage context as a diagnostic tool for AiTFL integrity in a pediatric population as it shows good sensitivity and excellent specificity.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3