Measuring Serum Vedolizumab and Vedolizumab Antibodies: Comparison of Commercial Assays with the Vedolizumab Clinical Development Assay

Author:

Vande Casteele Niels1ORCID,Yang Lili2,Dobler Iwona2,Agboton Christian3,McRorie Osborn Teresa24,Suri Ajit2,Lindner Dirk3,Smithson Glennda M.2

Affiliation:

1. Department of Medicine, University of California San Diego, School of Medicine, San Diego, California;

2. Takeda, Cambridge, Massachusetts;

3. Takeda, Zurich, Switzerland; and

4. Affiliation at the Time the Study Was Conducted.

Abstract

Background: Vedolizumab (VDZ) is an anti-α4β7 integrin monoclonal antibody approved for inflammatory bowel disease treatment. VDZ serum and antidrug antibody (ADA) concentrations may be used for treatment optimization. In this article, the results of 5 commercial assays (Grifols, Immundiagnostik, Progenika, Sanquin, and Theradiag) measuring VDZ concentration and ADA were compared with those of the reference assays used in VDZ clinical studies. Our findings will assist clinicians in interpreting commercial assay results in the context of VDZ clinical trial data. Methods: VDZ-treated patient samples were used to evaluate the agreement between commercial assays and the reference VDZ serum concentration assay, based on linear regression, Bland–Altman, and qualitative agreement analyses. VDZ ADAs were detected using qualitative assays. Specificity, selectivity, accuracy, and precision were assessed using serum samples from healthy donors or patients with IBD (VDZ serum concentration <0.5 mcg/mL) spiked with VDZ, with/without other biologics (identical sample sets per assay). Results: All assays were specific and selective for VDZ. Overall, the commercial assay results for VDZ-spiked samples correlated well with those of the reference serum concentration assay (R2 ≥ 0.98). Compared with the Immundiagnostik and Theradiag assays, the Grifols, Sanquin, and Progenika assays had the best reference assay agreement (based on regression analysis, Bland–Altman plots, and qualitative agreement [Cohen's kappa ≥0.92]). All immunogenicity assays detected VDZ ADAs; only the reference assay detected VDZ ADAs in the presence of 15 mcg/mL VDZ, advising caution with commercial ADA assays if VDZ is present. Conclusions: All 5 commercial assays are suitable for VDZ therapeutic monitoring and ADA testing. However, the absolute values from the reference assays and the different commercial assays were not comparable, indicating that the same assay must be used for repeated monitoring of VDZ serum concentrations.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Pharmacology (medical),Pharmacology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3