Abstract

Background: Intravenous high-dose methotrexate (MTX ≥ 1 g/m2) is frequently used in patients with cerebral lymphoma or other malignancies. In addition to its potent efficacy, it is known to have pronounced toxicity and life-threatening side effects. Regular-level monitoring at short and defined intervals is mandatory. This study aimed to evaluate the possibility of replacing peripheral blood sampling with blood samples from central venous catheters for therapeutic monitoring of MTX in adults. Methods: A total of 6 patients and 7 cycles of chemotherapy (6 females; 5 with cerebral non-Hodgkin lymphoma and 1 with osteosarcoma, median age 51 years; range 33–62 years) were included. An immunoassay was used for quantitative analysis of MTX levels. The measurement points were obtained in the time intervals of 24, 42, 48, and 72 hours, and afterward, every 24 hours until the level was below <0.1 µmol/L. After flushing with 10 mL of saline solution and discarding 10 mL of venous blood, blood was drawn from the central venous access through which MTX had previously been administered. Simultaneously, MTX levels were obtained from peripheral venipuncture. Results: Methotrexate levels from central venous access and MTX levels from peripheral venipuncture showed a significant correlation (r = 0.998; P < 0.01; n = 35). During withdrawal from the central access group, 17 values showed a lower MTX level, 10 showed a higher level, and 8 showed no difference. However, the MTX level difference was not significant (P = 0.997, linear mixed model). No increase in the dose of calcium folinate was necessary based on the collected MTX levels. Conclusions: In adults, MTX monitoring from central venous access is not inferior to monitoring from peripheral venipuncture. Repeated venipuncture to measure MTX levels can be replaced after establishing standardized instructions for proper sampling by a central venous catheter.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Pharmacology (medical),Pharmacology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3