A Novel LC-MS/MS Method for Therapeutic Drug Monitoring of Baricitinib in Plasma of Pediatric Patients

Author:

Cafaro Alessia1,Baiardi Giammarco23,Pigliasco Federica1,Barco Sebastiano1,Mattioli Francesca23,Volpi Stefano4,Caorsi Roberta4,Gattorno Marco4,Cangemi Giuliana1

Affiliation:

1. Chromatography and Mass Spectrometry Section, Central Laboratory of Analysis, IRCCS Istituto Giannina Gaslini;

2. Department of Internal Medicine, Pharmacology, and Toxicology Unit, University of Genoa, Viale Benedetto XV;

3. Clinical Pharmacology Unit, EO Ospedali Galliera, Mura delle Cappuccine; and

4. UOC Reumatologia e Malattie Autoinfiammatorie, IRCCS Istituto Giannina Gaslini, Genoa, Italy.

Abstract

Background: Janus kinase inhibitors are antirheumatic immunosuppressive drugs that target intracellular Janus kinases (JAKs). Baricitinib is a selective and reversible orally administered JAK1/JAK2 inhibitor approved for treating rheumatoid arthritis, atopic dermatitis, and alopecia areata in adult patients. Expanded access to baricitinib has been approved for treating pediatric patients affected by rare Mendelian autoinflammatory diseases with type I interferon-mediated damage. Knowledge of the pharmacokinetic properties and target plasma levels of baricitinib in pediatric patients is limited. In this study, a novel LC-MS/MS method for measuring baricitinib in plasma, validated according to the ICH M10 guidelines, is presented. Methods: Sample preparation was performed by adding 10 µL of IS working solution (150 ng/mL) and 200 µL of MeOH to each plasma sample. Chromatographic separation was conducted using a Thermo Scientific Accucore Polar Premium column (50 mm × 2.1 mm, i.d. 2.6 m). This method was applied to 7 real anonymous plasma samples obtained from pediatric patients treated with baricitinib at IRCCS Istituto Giannina Gaslini (Genoa, Italy). Patients of both sexes had a median age of 14 years (range, 10–17 years). Results: The LC-MS/MS method resulted linear over wide concentration ranges (1.024–100 ng/mL) and was accurate and reproducible in the absence of matrix effects, allowing for robust, specific, and rapid quantification of baricitinib from a low amount of plasma (50 µL). The plasma concentration of baricitinib in the samples of the patients, expressed as mean ± SD, was 11.25 ± 10.86 ng/mL. Conclusions: This novel LC-MS/MS method is suitable for the therapeutic drug monitoring of baricitinib and can help guide therapy optimization in pediatric patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Pharmacology (medical),Pharmacology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Baricitinib treatment in children with COPA syndrome;The Journal of Allergy and Clinical Immunology: In Practice;2024-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3